Evidence map›Paper›PMID 30917189›Full record

ArticlePloS one2019

Depth measurement of molecular permeation using inclined confocal microscopy.

Kenji Kikuchi, Shunsuke Shigeta, Takuji Ishikawa

Abstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Kenji KikuchiDepartment of Finemechanics, Graduate School of Engineering, Tohoku University, Aramaki, Aoba, Sendai, Japan.ORCID 0000-0001-8187-6773
Shunsuke ShigetaDepartment of Finemechanics, Graduate School of Engineering, Tohoku University, Aramaki, Aoba, Sendai, Japan.
Takuji IshikawaDepartment of Finemechanics, Graduate School of Engineering, Tohoku University, Aramaki, Aoba, Sendai, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We report a new technique for the high time-resolved depth measurement of molecular concentration distribution in a permeable hydrogel film with micro-depth precision. We developed an inclined observation technique in a laser-induced fluorescence (LIF) system, based on confocal microscopy, which measures the concentration distribution in the depth direction at less than micrometre intervals. The focal plane of confocal microscopy was tilted to enable simultaneous depth scanning in the microscopic field of view inside the permeable substrate. Our system achieved real-time and non-contact depth measurement of concentration distribution in the permeable hydrogel film. Simultaneous depth concentration measurement was realised with < 1 μm/pixel resolution over a maximum depth range of 570 μm, depending on the tilt angle of the stage and optical conditions. Our system measured the concentration of fluorescence materials based on the fluorescence intensities at several depth positions with a minimum concentration resolution of 1.3 nmol/L. Applying the proposed system to real-time concentration imaging, we successfully visualised unsteady concentration transport phenomena, and estimated the mass transport coefficient through the liquid-hydrogel interface. Our findings are useful for investigating the mass transport of physical, biological, and medical phenomena in permeable substrates.

Indexed as

FluorescenceHydrogelsLasersMicroscopy, ConfocalPermeabilityTime FactorsHydrogels

Identifiers

PMID30917189
PMCPMC6436738

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.