Evidence map›Paper›PMID 30913103›Full record

ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)2020

Estimation of Central Venous Pressure by Pacemaker Lead Impedances in Left Ventricular Assist Device Patients.

Teruhiko Imamura, Joshua D Moss, Erin Flatley, Daniel Rodgers, Gene Kim, Jayant Raikhelkar, Nitasha Sarswat, Sara Kalantari, Ann Nguyen, Colleen Juricek and 6 more

Abstract read
In one paragraph

Article in ASAIO journal (American Society for Artificial Internal Organs : 1992), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

Teruhiko ImamuraFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Joshua D MossFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Erin FlatleyFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Daniel RodgersFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Gene KimFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Jayant RaikhelkarFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Nitasha SarswatFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Sara KalantariFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Ann NguyenFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Colleen JuricekDepartment of Surgery, University of Chicago Medical Center, Chicago, Illinois.
Daniel BurkhoffColumbia University Medical Center, and Cardiovascular Research Foundation, New York, New York.
Tae SongDepartment of Surgery, University of Chicago Medical Center, Chicago, Illinois.
Takeyoshi OtaDepartment of Surgery, University of Chicago Medical Center, Chicago, Illinois.
Valluvan JeevanandamDepartment of Surgery, University of Chicago Medical Center, Chicago, Illinois.
Gabriel SayerFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Nir UrielFrom the Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.

Funding

MULTIDISCIPLINARY CARDIAC SCIENCEST32HL007381 · NHLBI · UNIVERSITY OF CHICAGO · PI JEANNE M DECARA, Yoav Gilad · 1985 to 2026
$12.5M
NHLBI NIH HHS T32 HL007381
6 · The paper itself

Abstract

Volume status assessment in left ventricular assist device (LVAD) patients remains challenging. Cardiac resynchronization therapy (CRT) devices are common in LVAD patients, and the impedance across the CRT leads may be associated with hemodynamics and serve as a tool for noninvasive estimation of volume status. Ninety-one sets of measurements including cardiac filling pressures and lead impedances were prospectively obtained during ramp tests from 11 LVAD patients (65.5 ± 9.7 years old; nine male) with CRT devices. Right atrial (RA), right ventricular (RV), and left ventricular (LV) lead impedances were all significantly associated with central venous pressure (CVP) (p < 0.05). We derived the following equation: estimated CVP = 47.90-(0.086 × RA lead impedance) + (0.013 × RV lead impedance)-(0.020 × LV lead impedance). The estimated CVP had a significant correlation (r = 0.795) and good agreement with the measured CVP (mean difference -0.14 ± 1.77 mmHg). Applying the above equation on the validation cohort of twenty-one patients also maintained a strong association with measured CVP (r = 0.705). In conclusion, we have derived a novel equation to estimate CVP using lead impedance measurements. This finding may allow noninvasive monitoring of volume status in LVAD patients.

Indexed as

Central Venous PressureElectric ImpedanceHeart-Assist DevicesMathematical ConceptsPacemaker, ArtificialAgedCohort StudiesFemaleHeart FailureHeart VentriclesHemodynamicsHumansMaleMiddle Aged

Identifiers

PMID30913103
PMCPMC7081837

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.