Trial reportThe international journal of cardiovascular imaging2019
The relationship of pre-procedural Dmax based sizing to lesion level outcomes in Absorb BVS and Xience EES treated patients in the AIDA trial.
Trial report in The international journal of cardiovascular imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Three-year clinical outcomes of the absorb bioresorbable vascular scaffold compared to Xience everolimus-eluting stent in routine PCI in patients with diabetes mellitus-AIDA sub-study.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2021Trial
- Impact of lesion preparation and stent optimisation on lesion-oriented events in PCI with drug-eluting stents: 5-year results from the AIDA trial.Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2025Article
- Endovascular Drug Delivery.Life (Basel, Switzerland) · 2024Review
- Vascular Lesion-Specific Drug Delivery Systems: JACC State-of-the-Art Review.Journal of the American College of Cardiology · 2021Review
- Cardiovascular imaging 2019 in the International Journal of Cardiovascular Imaging.The international journal of cardiovascular imaging · 2020Article
- The Absorb bioresorbable vascular scaffold in real-world practice: long-term follow-up of the AMC Single Centre Real World PCI Registry.Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
25 authors.
Funding
Abstract
Due to expansion limits of the Absorb bioresorbable scaffold a meticulous implantation with correct sizing is required. We sought to investigate the clinical outcomes based on the sizing of the device related to the maximal lumen diameter measured by quantitative coronary angiography in Absorb BVS and Xience EES treated lesions in the AIDA trial. Sizing of Absorb bioresorbable vascular scaffold (BVS) and Xience everolimus eluting stent (EES) was graded according to the definitions of device non-oversize and device oversize on pre-procedural angiography. Lesion-oriented outcomes (LOCE) (device thrombosis, TLR and TVMI) that occurred during 2 years follow-up were related to device non-oversized or oversized status. In the Absorb BVS group, LOCE occurred in 48 (7.4%) lesions in the oversized group and in 32 (8.2%) lesions in the non-oversized group (HR 0.91; 95% CI 0.58-1.42; p = 0.681), whereas TLR occurred in 34 (5.3%) lesions and in 23 lesions (5.9%), respectively (HR 0.89; 95% CI 0.52-1.51; p = 0.666). Definite scaffold thrombosis occurred in 11 (1.7%) device oversized treated lesions against 16 (4.1%) device non-oversized treated lesions (HR 0.41; 95% CI 0.19-0.89; p = 0.020). There were no differences in event rates between oversized and non-oversized groups in lesions treated with Xience EES. There was no significant difference in LOCE between oversized and non-oversized treated Absorb BVS and Xience EES treated lesions. Non-oversized Absorb BVS implantation was associated with a higher risk of scaffold thrombosis at complete 2 years follow-up. The majority of very late scaffold thrombosis occurred in properly sized devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.