Evidence map›Paper›PMID 30907763›Full record

ArticleAnesthesiology2019

Extracorporeal Arteriovenous Ultrasound Measurement of Cardiac Output in Small Children.

Theodor S Sigurdsson, Anders Aronsson, Lars Lindberg

Abstract read
PubMed Publisher
In one paragraph

Article in Anesthesiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Indexing haemodynamic variables in young children.Acta anaesthesiologica Scandinavica · 2021
    Observational
  4. Review
  5. Observational
  6. Fluid responsiveness in the pediatric population.Korean journal of anesthesiology · 2019
    Review
  7. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Theodor S SigurdssonFrom the Department of Pediatric Anesthesiology and Intensive Care Medicine, Children's Hospital, University Hospital of Lund, Lund, Sweden (T.S.S., A.A., L.L.) the Department of Anesthesiology and Intensive Care Medicine, Landspítalinn, University Hospital of Iceland, Reykjavík, Iceland (T.S.S.).
Anders Aronsson
Lars Lindberg

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTechnology for cardiac output (CO) and blood volume measurements has been developed based on blood dilution with a small bolus of physiologic body temperature saline, which, after transcardiopulmonary mixing, is detected with ultrasound sensors attached to an extracorporeal arteriovenous loop using existing central venous and peripheral arterial catheters. This study aims to compare the precision and agreement of this technology to measure cardiac output with a reference method, a perivascular flow probe placed around the aorta, in young children. The null hypothesis is that the methods are equivalent in precision, and there is no bias in the cardiac output measurements.

methodsForty-three children scheduled for cardiac surgery were included in this prospective single-center comparison study. After corrective cardiac surgery, five consecutive repeated cardiac output measurements were performed simultaneously by both methods.

resultsA total of 215 cardiac output measurements were compared in 43 children. The mean age of the children was 354 days (range, 30 to 1,303 days), and the mean weight was 7.1 kg (range, 2.7 to 13.6 kg). The precision assessed as two times the coefficient of error was 3.6% for the ultrasound method and 5.0% for the flow probe. Bias (mean COultrasound 1.28 l/min - mean COflow probe 1.20 l/min) was 0.08 l/min, limits of agreement was ±0.32 l/min, and the percentage error was 26.6%.

conclusionsThe technology to measure cardiac output with ultrasound detection of blood dilution after a bolus injection of saline yields comparable precision as cardiac output measurements by a periaortic flow probe. The difference in accuracy in the measured cardiac output between the methods can be explained by the coronary blood flow, which is excluded in the cardiac output measurements by the periaortic flow probe.

Indexed as

Cardiac OutputCardiac Surgical ProceduresChild, PreschoolCoronary CirculationHumansInfantProspective StudiesUltrasonography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked