Evidence map›Paper›PMID 30905974›Full record

ArticleIEEE transactions on nuclear science2018

Light Spread Manipulation in Scintillators Using Laser Induced Optical Barriers.

Lisa Bläckberg, Michael Moebius, Georges El Fakhri, Eric Mazur, Hamid Sabet

Abstract read
In one paragraph

Article in IEEE transactions on nuclear science, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lisa BläckbergDept. of Radiolgy at Massachusetts General Hospital and Harvard Medical School, Boston, USA, and Dept. of Physics and Astronomy, Uppsala University, Sweden (LBlackberg@MGH.Harvard.edu).
Michael MoebiusSchool of Engineering and Applied Sciences, Harvard University. He is now with The Charles Stark Draper Laboratory.
Georges El FakhriDept. of Radiology at Massachusetts General Hospital and Harvard Medical School, Boston, USA.
Eric MazurSchool of Engineering and Applied Sciences, Harvard University.
Hamid SabetDept. of Radiology at Massachusetts General Hospital and Harvard Medical School, Boston, USA. (HSabet@MGH.Harvard.edu).

Funding

Novel laser-processed scintillation detector for high-resolution PET scannersR21EB020162 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI SABET, HAMID · 2016 to 2017
$488k
NIBIB NIH HHS R21 EB020162
6 · The paper itself

Abstract

We are using the Laser Induced Optical Barriers (LIOB) technique to fabricate scintillator detectors with combined performance characteristics of the two standard detector types, mechanically pixelated arrays and monolithic crystals. This is done by incorporation of so-called optical barriers that have a refractive index lower than that of the crystal bulk. Such barriers can redirect the scintillation light and allow for control of the light spread in the detector. Previous work has shown that the LIOB technique has the potential to achieve detectors with high transversal and depth of interaction (DOI) resolution simultaneously in a single-side readout configuration, suitable for high resolution PET imaging. However, all designs studied thus far present edge effect issues similarly as in the standard detector categories. In this work we take advantage of the inherent flexibility of the LIOB technique and investigate alternative barrier patterns with the aim to address this problem. Light transport simulations of barrier patterns in LYSO:Ce, with deeper barrier walls moving towards the detector edge show great promise in reducing the edge effect, however there is a trade-off in terms of achievable DOI information. Furthermore, fabrication and characterization of a 20 mm thick LYSO:Ce detector with optical barriers forming a pattern of 1 × 1 × 20mm

Indexed as

Depth of interaction (DOI)detector fabricationhigh-resolutionLaser Induced Optical Barrierslight transport simulationsLYSO:CePET

Identifiers

PMID30905974
PMCPMC6424510

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.