Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Performance of the entirely subcutaneous ICD in borderline indications.Clinical research in cardiology : official journal of the German Cardiac Society · 2020
    Article
  3. Outcome differences and device performance of the subcutaneous ICD in patients with and without structural heart disease.Clinical research in cardiology : official journal of the German Cardiac Society · 2020
    Article
  4. Clinical experience regarding safety and diagnostic value of cardiovascular magnetic resonance in patients with a subcutaneous implanted cardioverter/defibrillator (S-ICD) at 1.5 T.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Kevin WillyClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Markus BettinClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Florian ReinkeClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Nils BögeholzClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Christian EllermannClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Benjamin RathClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Patrick LeitzClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Julia KöbeClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Lars EckardtClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Gerrit FrommeyerClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany. gerrit.frommeyer@ukmuenster.de.ORCID http://orcid.org/0000-0002-1431-9886
University Hospital Münster · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe subcutaneous ICD (S-ICD™) is an important advance in device therapy for the prevention of sudden cardiac death (SCD). Although current guidelines recommend S-ICD™ use, long-term data are still limited, especially in subgroups. Among several cardiac diseases that prone to SCD, coronary artery disease (CAD) carries several peculiarities that may hamper S-ICD™ therapy in this cohort. CAD can lead to an ischemic cardiomyopathy (ICM) with a reduced left-ventricular ejection fraction (LVEF) and bundle branch blocks, which can be difficult for ICD sensing and discrimination of arrhythmia. CAD is mainly driven by risk factors such as diabetes mellitus, which put these patients at an elevated risk for infectious complications of cardiac devices. Furthermore, in ICM myocardial scars are frequent and are a potential substrate for ventricular tachycardia, which may be accessible for antitachycardia pacing. At the moment, it remains unclear if there is a value of S-ICD™ therapy in this subgroup. Therefore, this study analysed patients with CAD. MATERIALS AND

methodsAll S-ICD™ patients with CAD as the main indication for ICD implantation (n = 45 patients) in our large-scaled single-center S-ICD™ registry (n = 249 patients) were included in this study. Baseline characteristics, appropriate and inappropriate shocks, and complications were documented in a mean follow-up of 22.5 ± 8.3 months.

resultsPrimary prevention of SCD was the indication for implantation of an S-ICD™ in 28 patients (62%). Of all 45 patients with an overall mean age of 58.1 ± 11.4 years, 40 were male (88%). The mean LVEF was 37.7 ± 12.6%. Three episodes of ventricular arrhythmia (one monomorphic, one polymorphic, one ventricular fibrillation) were adequately terminated in three patients (7%). In only one patient, oversensing resulting in an inappropriate shock was observed, which could be managed by changing the sensing vector. 15 of the examined 45 patients previously had a transvenous ICD, which was explanted due to system-related infections. In only two patients, S-ICD™ was changed to transvenous ICD because of the need of antibradycardia stimulation. There were no S-ICD™ system-related infections.

conclusionThe S-ICD™ seems to be a valuable option for the prevention of SCD in CAD patients. Patients with systemic infections of a transvenous ICD and, therefore, a need for an alternative might benefit from the absence of intracardiac leads as the S-ICD™ is safe and works flawlessly in these patients. Inadequate shock delivery was very rare, while every episode of ventricular arrhythmia was terminated by the first shock.

Indexed as

Defibrillators, ImplantableAgedCohort StudiesCoronary Artery DiseaseDeath, Sudden, CardiacFeasibility StudiesFemaleHumansMaleMiddle AgedRisk FactorsTreatment OutcomeCoronary artery diseaseSubcutaneous ICDSudden cardiac death

Identifiers

PMID30903274
OpenAlexW2935687270

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.