In one paragraph

Article in Diabetes technology & therapeutics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
3.8field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 35 citations in OpenAlex.

  1. Trial
  2. A Mini-Patch Magnetic Insulin Pump for Enhanced Delivery Resolution and Accuracy.Advanced intelligent systems (Weinheim an der Bergstrasse, Germany) · 2026
    Article
  3. Insulin Pumps for Individuals With Type 2 Diabetes.Diabetes spectrum : a publication of the American Diabetes Association · 2025
    Article
  4. Article
  5. Article
  6. Microfluidic-based systems for the management of diabetes.Drug delivery and translational research · 2024
    Review
  7. Article
  8. Article
  9. Article
  10. Patch Pumps: Periodic Insulin Delivery Patterns.Journal of diabetes science and technology · 2023
    Article
  11. Article
  12. Article
  13. Insulin Delivery Hardware: Pumps and Pens.Diabetes technology & therapeutics · 2022
    Article
  14. Insulin Pumps.Diabetes technology & therapeutics · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Guido Freckmann1 Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Ulrike Kamecke1 Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Delia Waldenmaier1 Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Cornelia Haug1 Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Ralph Ziegler2 Diabetes Clinic for Children and Adolescents, Muenster, Germany.
Universität Ulm · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInsulin pumps are used for basal rate and bolus insulin delivery in patients with diabetes. In this in vitro study, accuracy of delivery of different commercial insulin pumps was evaluated. MATERIALS AND

methodsAccuracy of 10 different insulin pump systems (5 durable pumps with different insulin infusion sets and 1 patch pump) was tested with a microgravimetric method. Mean bolus accuracy of 25 successive 1 U boluses and of 12 successive 10 U boluses was assessed, and delivery time for 10 U boluses was measured. Basal rate accuracy at 1.0 U/h was evaluated for 72 h and for individual 1-h windows.

resultsMean bolus delivery was within ±5% of target for both tested bolus sizes, but precision of individual boluses was higher with the larger boluses. Delivery times varied between the different pump models but agreed with the specifications of the respective manufacturers. Regarding basal rate accuracy, the total deviation for 72 h was very small in all pumps; however, larger deviations were observed during the first 12 h. For the patch pump, large variations between individual 1-h windows were observed.

conclusionsIn general, all compared insulin pump systems showed a similar level of accuracy. Differences, especially between durable pumps and the patch pump, were observed when considering each hour of basal rate delivery separately.

Indexed as

Insulin Infusion SystemsMaterials TestingDiabetes Mellitus, Type 1HumansHypoglycemic AgentsInsulinHypoglycemic AgentsInsulinAccuracyBasal rateBolusContinuous subcutaneous insulin infusionInsulin pump

Identifiers

PMID30901232
PMCPMC6477586
OpenAlexW2928935173

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.