Evidence map›Paper›PMID 30900114›Full record

ArticleInternational journal of computer assisted radiology and surgery2019

Estimation of tissue oxygen saturation from RGB images and sparse hyperspectral signals based on conditional generative adversarial network.

Qingbiao Li, Jianyu Lin, Neil T Clancy, Daniel S Elson

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Surgical spectral imaging.Medical image analysis · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Qingbiao LiThe Hamlyn Centre for Robotic Surgery, Imperial College London, London, UK. ql716@ic.ac.uk.ORCID http://orcid.org/0000-0003-2761-1218
Jianyu LinThe Hamlyn Centre for Robotic Surgery, Imperial College London, London, UK.
Neil T ClancyWellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK.
Daniel S ElsonThe Hamlyn Centre for Robotic Surgery, Imperial College London, London, UK.

Funding

Medical Research Council MC_PC_13064
6 · The paper itself

Abstract

purposeIntra-operative measurement of tissue oxygen saturation ([Formula: see text]) is important in detection of ischaemia, monitoring perfusion and identifying disease. Hyperspectral imaging (HSI) measures the optical reflectance spectrum of the tissue and uses this information to quantify its composition, including [Formula: see text]. However, real-time monitoring is difficult due to capture rate and data processing time.

methodsAn endoscopic system based on a multi-fibre probe was previously developed to sparsely capture HSI data (sHSI). These were combined with RGB images, via a deep neural network, to generate high-resolution hypercubes and calculate [Formula: see text]. To improve accuracy and processing speed, we propose a dual-input conditional generative adversarial network, Dual2StO2, to directly estimate [Formula: see text] by fusing features from both RGB and sHSI.

resultsValidation experiments were carried out on in vivo porcine bowel data, where the ground truth [Formula: see text] was generated from the HSI camera. Performance was also compared to our previous super-spectral-resolution network, SSRNet in terms of mean [Formula: see text] prediction accuracy and structural similarity metrics. Dual2StO2 was also tested using simulated probe data with varying fibre number.

conclusions[Formula: see text] estimation by Dual2StO2 is visually closer to ground truth in general structure and achieves higher prediction accuracy and faster processing speed than SSRNet. Simulations showed that results improved when a greater number of fibres are used in the probe. Future work will include refinement of the network architecture, hardware optimization based on simulation results, and evaluation of the technique in clinical applications beyond [Formula: see text] estimation.

Indexed as

OxygenAnimalsIntestinesIschemiaOptical ImagingSwineOxygenGenerative adversarial networkIntro-operative imagingOptical imagingTissue oxygen saturation

Identifiers

PMID30900114
PMCPMC6544606

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.