Evidence map›Paper›PMID 30897894›Full record

ArticleKidney research and clinical practice2019

Evaluation of different bioimpedance methods for assessing body composition in Asian non-dialysis chronic kidney disease patients.

Sean Wy Lee, Clara Lee Ying Ngoh, Horng Ruey Chua, Sabrina Haroon, Weng Kin Wong, Evan Jc Lee, Titus Wl Lau, Sunil Sethi, Boon Wee Teo

Open access · diamondAbstract read
In one paragraph

Article in Kidney research and clinical practice, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Sean Wy LeeDivision of Nephrology, Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
Clara Lee Ying NgohDivision of Nephrology, Department of Medicine, National University Health System, Singapore.
Horng Ruey ChuaDivision of Nephrology, Department of Medicine, National University Health System, Singapore.
Sabrina HaroonDivision of Nephrology, Department of Medicine, National University Health System, Singapore.
Weng Kin WongDivision of Nephrology, Department of Medicine, National University Health System, Singapore.
Evan Jc LeeDivision of Nephrology, Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
Titus Wl LauDivision of Nephrology, Department of Medicine, National University Health System, Singapore.
Sunil SethiDepartment of Pathology, National University Health System, Singapore.
Boon Wee TeoDivision of Nephrology, Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.ORCID http://orcid.org/0000-0002-4911-8507
National University Health System · SGNational University of Singapore · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundChronic kidney disease (CKD) is associated with fluid retention, which increases total body water (TBW) and leads to changes in intracellular water (ICW) and extracellular water (ECW). This complicates accurate assessments of body composition. Analysis of bioelectrical impedance may improve the accuracy of evaluation in CKD patients and multiple machines and technologies are available. We compared body composition by bioimpedance spectroscopy (BIS) against multi-frequency bioimpedance analysis (BIA) in a multi-ethnic Asian population of stable, non-dialysis CKD patients.

methodsWe recruited 98 stable CKD patients comprising 54.1% men and 70.4% Chinese, 9.2% Malay, 13.3% Indian, and 8.2% other ethnicities. Stability was defined as no variation in serum creatinine > 20% over three months. Patients underwent BIS analyses using a Fresenius body composition monitor, while BIA analyses employed a Bodystat Quadscan 4000.

resultsMean TBW values by BIS and BIA were 33.6 ± 7.2 L and 38.3 ± 7.4 L; mean ECW values were 15.8 ± 3.2 L and 16.9 ± 2.7 L; and mean ICW values were 17.9 ± 4.3 L and 21.0 ± 4.9 L, respectively. Mean differences for TBW were 4.6 ± 1.9 L (

conclusionAlthough both BIA and BIS can be used for body water assessment, clinicians should be aware of biases that exist between bioimpedance techniques. The values of body water assessments in our study were higher in BIA than in BIS. Ethnicity, sex, body mass index, and estimated glomerular filtration rate were associated with these biases.

Indexed as

AdultBody compositionBody waterElectric impedanceKidney diseasesNutrition assessment

Identifiers

PMID30897894
PMCPMC6481966
OpenAlexW2924538499

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.