Evidence map›Paper›PMID 30895187›Full record

ArticleERJ open research2019

Interdevice agreement in respiratory resistance values by oscillometry in asthmatic children.

Francine M Ducharme, Imane Jroundi, Guillaume Jean, Guillaume Lavoie Boutin, Christiane Lawson, Benjamin Vinet

Registry-linked trialAbstract read
In one paragraph

Article in ERJ open research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04903145 (Proof-of-concept of the Measurement of Lung Function Using the Relaxed Expiratory Occlusion Monitor), which is not on this map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04903145 unknown statusnot on this mapstarted 2021, after this paper: background citation

Proof-of-concept of the Measurement of Lung Function Using the Relaxed Expiratory Occlusion Monitor (REOM)

TypeobservationalSponsorThorasys Thoracic Medical Systems Inc.Ran2021 to 2022Enrolled45ConditionsAsthma in ChildrenArmsREOM
3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Oscillometry for the diagnosis of asthma in children: a systematic review.European respiratory review : an official journal of the European Respiratory Society · 2026
    Pooled it
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Do impulse oscillometry parameters differ between children and adolescents with symptoms of rhinitis and those without?Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia · 2022
    Article
  8. Oscillometry of the respiratory system: a translational opportunity not to be missed.American journal of physiology. Lung cellular and molecular physiology · 2021
    Review
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Francine M DucharmeDept of Pediatrics, University of Montreal, Montreal, QC, Canada.ORCID https://orcid.org/0000-0001-5096-0614
Imane JroundiClinical Research on Childhood Asthma Research Unit, Research Centre, Sainte-Justine University Health Centre, Montreal, QC, Canada.
Guillaume JeanClinical Research on Childhood Asthma Research Unit, Research Centre, Sainte-Justine University Health Centre, Montreal, QC, Canada.
Guillaume Lavoie BoutinClinical Research on Childhood Asthma Research Unit, Research Centre, Sainte-Justine University Health Centre, Montreal, QC, Canada.
Christiane LawsonClinical Research on Childhood Asthma Research Unit, Research Centre, Sainte-Justine University Health Centre, Montreal, QC, Canada.
Benjamin VinetClinical Research on Childhood Asthma Research Unit, Research Centre, Sainte-Justine University Health Centre, Montreal, QC, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWith several commercially available devices measuring respiratory impedance by oscillometry, the agreement between values obtained on different instruments or frequencies remains unclear. Our aim was to examine the agreement between resistance and reactance parameters on two oscillometry instruments using different waveforms.

methodsWe conducted a prospective cross-sectional study in asthmatic children aged 3-17 years. Reproducible oscillometry measurements were obtained in random order, by blinded operators, at three modes: 5-10-15-20-25 Hz (5-25 Hz) multifrequency mode on the MasterScreen impulse oscillometry system, and both 5-25 Hz multifrequency mode and 7 Hz monofrequency on the tremoFlo C-100 airwave sinusoidal system. Resistance, reactance and within-breath parameters were examined using the intraclass correlation coefficient (ICC), paired t-test, linear regression and Bland-Altman method.

resultsOf 50 participants, 44 and 38 completed between-device and within-frequency measurements, respectively. Between-device measurements at 5-25 Hz showed high (ICC 0.88-0.91) and good (ICC 0.69-0.87) agreement in resistance and reactance, respectively, but with an absolute within-patient difference (≥0.05 kPa·L

conclusionObserved differences in resistance and reactance suggest the need for instrument- and frequency-specific paediatric normative values.

Identifiers

PMID30895187
PMCPMC6421362

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials