Evidence map›Paper›PMID 30889149›Full record

ReviewActa bio-medica : Atenei Parmensis2019

Computer-assisted surgery in total knee replacement: advantages, surgical procedure and review of the literature.

Norberto Confalonieri, Alessio Biazzo

Open access · greenAbstract readReview
In one paragraph

Review in Acta bio-medica : Atenei Parmensis, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 19 citations in OpenAlex.

  1. Porous Triboelectric Nanogenerator for Load Sensing of Total Knee Replacement.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. [Robotics and computer-assisted surgery].Chirurgie (Heidelberg, Germany) · 2023
    Article
  10. A single type of varus knee does not exist: morphotyping and gap analysis in varus OA.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022
    Article
  11. Article
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Norberto ConfalonieriGaetano Pini-CTO, Milano. norberto.confalonieri@gmail.com.
Alessio Biazzo
Istituto Ortopedico Gaetano Pini · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionTotal knee replacement (TKR) is one of the most frequent orthopaedic procedures performed every year. At the same time 20% of patients who underwent TKR are not satisfied with the outcome. The reasons are unknown; we think that a mechanical alignment beyond 3° of varus-valgus can represent the most important cause of failure of TKR and consequently patient dissatisfaction. MATERIALS AND

methodsNeutral mechanical alignment is the main goal in every TKR: this can be achieved through different tools, such as extramedullary and intramedullary guides, patient-specific instrumentation (PSI) and computer-assisted surgery (CAS). The aim of this review is to compare the different alignment techniques in TKR, to describe CAS procedure and CAS results in recent literature.

resultsRegarding the intramedullary guide, there is an increased risk of fatty embolism; there are great limitations on its use, or even impossibility, in cases of bone deformity and sequelae of trauma. Regarding the extramedullary guide, it becomes more difficult to use in cases of great obesity or increased soft-tissue volume around the tibia. PSI for TKR has been introduced to improve alignment, reduce outliers, operation time and the risk of fatty embolism by avoidance of intramedullary canal violation. Recent randomized controlled trials and meta-analysis proved no advantage of PSI in improving mechanical axis and implant survivorship. DISCUSSION: CAS has provided to be a useful tool in assisting the surgeon to achieve more accurate post-operative mechanical axis through precise and reproducible bone cuts and ligament balancing. Two meta-analyses definitively proved that CAS technique improves mechanical axis and implant survivorship and one recent meta-analysis demonstrated that CAS provides better mechanical alignment and higher functional scores at short-term follow-up.

Indexed as

Arthroplasty, Replacement, KneeHumansSurgery, Computer-Assisted

Identifiers

PMID30889149
PMCPMC6502163
OpenAlexW3008362877

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.