Evidence map›Paper›PMID 30888348›Full record

ArticleThe Analyst2019

An implanted pH sensor read using radiography.

Md Arifuzzaman, Paul W Millhouse, Yash Raval, Thomas B Pace, Caleb J Behrend, Shayesteh Beladi Behbahani, John D DesJardins, Tzuen-Rong J Tzeng, Jeffrey N Anker

Abstract read
In one paragraph

Article in The Analyst, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. FITC-Labeled Alendronate as an In Vivo Bone pH Sensor.BioMed research international · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Md ArifuzzamanDepartment of Chemistry, Clemson University, Clemson, SC, USA. janker@clemson.edu marifuz@g.clemson.edu.
Paul W Millhouse
Yash Raval
Thomas B Pace
Caleb J Behrend
Shayesteh Beladi Behbahani
John D DesJardins
Tzuen-Rong J Tzeng
Jeffrey N Anker

Funding

Targeted Nano-therapeutics for Neural RegenerationP20GM103444 · NIGMS · CLEMSON UNIVERSITY · PI MARKWALD, ROGER R, VYAVAHARE, NAREN R · 2012 to 2018
$14.9M
Detecting and Monitoring Implant Infection Using X-ray Excited Luminescence Chemical Imaging (XELCI)R01AR070305 · NIAMS · CLEMSON UNIVERSITY · PI ANKER, JEFFREY N · 2016 to 2020
$1.6M
NIAMS NIH HHS R01 AR070305NIGMS NIH HHS P20 GM103444
6 · The paper itself

Abstract

A biomedical sensor was developed to measure local pH near orthopedic implants to detect and study implant-associated infection. The sensor is read using plain radiography, a technique which is noninvasive, inexpensive, ubiquitously available in medical facilities, and routinely used in diagnosis and follow-up. The sensor comprises a radiopaque tungsten indicator pin embedded within a chemically responsive hydrogel that exhibits a pH-dependent swelling. A stainless steel well holds this hydrogel and attaches to an orthopedic plate. The local pH may be determined from the extent of hydrogel swelling by radiographically measuring the indicator position relative to the well. We calibrated the sensor in a series of standard pH buffers and tested it during bacterial growth in culture. The sensor was robust: its response was negligibly affected by changes in temperature, ionic strength within the normal physiological range, or long-term incubation with reactive oxygen species generated from hydrogen peroxide and copper. Pooled data from several sensors fabricated at different times and tested in different conditions had a root-mean-square deviation from a pH electrode reading of 0.24 pH units. Radiographic measurements were also performed in cadaveric tissue with the sensor attached to an orthopedic plate fixed to a tibia. Pin position readings varied by 100 μm between observers surveying the same radiographs, corresponding to 0.065 pH units precision in the range pH 4-8. The sensor was designed to augment standard radiographs of tissue, bony anatomy, and hardware by also indicating local chemical concentrations.

Indexed as

Acrylic ResinsHumansHydrogelsHydrogen-Ion ConcentrationProstheses and ImplantsRadiographyStaphylococcus aureusAcrylic ResinsHydrogels

Identifiers

PMID30888348
PMCPMC6491216

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.