A New Blood Pulsation Simulator Platform Incorporating Cardiovascular Physiology for Evaluating Radial Pulse Waveform.

Tae-Heon Yang, Jaeuk U Kim, Young-Min Kim, Jeong-Hoi Koo, Sam-Yong Woo

Open access · hybridAbstract read
In one paragraph

Article in Journal of healthcare engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 2 countries.

Tae-Heon YangDepartment of Electronic Engineering, Korea National University of Transportation, Chungju-si 27469, Republic of Korea.ORCID 0000-0003-4316-4323
Jaeuk U KimFuture Medicine Division, Korea Institute of Oriental Medicine, Daejeon 34054, Republic of Korea.ORCID 0000-0003-0408-5569
Young-Min KimFuture Medicine Division, Korea Institute of Oriental Medicine, Daejeon 34054, Republic of Korea.
Jeong-Hoi KooDepartment of Mechanical and Manufacturing Engineering, Miami University, Oxford 45056, Ohio, USA.
Sam-Yong WooCenter for Mechanical Metrology, Korea Research Institute of Standards and Science, Daejeon 34113, Republic of Korea.ORCID 0000-0001-5990-781X
Korea Institute of Oriental Medicine · KRKorea National University of Transportation · KRKorea Research Institute of Standards and Science · KRMiami University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To meet the need for "standard" testing system for wearable blood pressure sensors, this study intends to develop a new radial pulsation simulator that can generate age-dependent reference radial artery pressure waveforms reflecting the physiological characteristics of human cardiovascular system. To closely duplicate a human cardiovascular system, the proposed simulator consists of a left ventricle simulation module, an aorta simulation module, a peripheral resistance simulation module, and a positive/negative pressure control reservoir module. Simulating physiologies of blood pressure, the compliance chamber in the simulator can control arterial stiffness to produce age-dependent pressure waveforms. The augmentation index was used to assess the pressure waveforms generated by the simulator. The test results show that the simulator can generate and control radial pressure waveforms similar to human pulse signals consisting of early systolic pressure, late systolic pressure, and dicrotic notch. Furthermore, the simulator's left ventricular pressure-volume loop results demonstrate that the simulator exhibits mechanical characteristics of the human cardiovascular system. The proposed device can be effectively used as a "standard" radial artery pressure simulator to calibrate the wearable sensor's measurement characteristics and to develop more advanced sensors. The simulator is intended to serve as a platform for the development, performance verification, and calibration of wearable blood pressure sensors. It will contribute to the advancement of the wearable blood pressure sensor technology, which enables real-time monitoring of users' radial artery pressure waveforms and eventually predicting cardiovascular diseases.

Indexed as

Models, CardiovascularAdultBlood PressureBlood Pressure DeterminationComputer SimulationEquipment DesignHeart RateHumansMiddle AgedPulseRadial ArterySignal Processing, Computer-AssistedYoung Adult

Identifiers

PMID30886685
PMCPMC6388329
OpenAlexW2913146881

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.