Evidence map›Paper›PMID 30885631›Full record

ArticleNeuroscience letters2019

Morphometric and computational assessments to evaluate neuron survival and maturation within compartmentalized microfluidic devices: The influence of design variation on diffusion-driven nutrient transport.

Angela R Dixon, Eric N Horst, Jeniffer J Garcia, Patricia R Ndjouyep-Yamaga, Geeta Mehta

Abstract read
In one paragraph

Article in Neuroscience letters, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Angela R DixonBiomedical Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, 48109, USA. Electronic address: mehtagee@umich.edu.
Eric N HorstBiomedical Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, 48109, USA; Material Science and Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, 48109, USA.
Jeniffer J GarciaNeuroscience, College of Literature, Science, and the Arts, University of Michigan, Ann Arbor, MI, 48109, USA.
Patricia R Ndjouyep-YamagaNeuroscience, College of Literature, Science, and the Arts, University of Michigan, Ann Arbor, MI, 48109, USA.
Geeta MehtaBiomedical Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, 48109, USA; Material Science and Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, 48109, USA; Macromolecular Science and Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, 48109, USA. Electronic address: dixangel@umich.edu.

Funding

Sensory Mechanisms and Disorders - Administrative SupplementT32DC000011 · NIDCD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Michael Thomas Roberts · 1989 to 2026
$9.5M
Department of Defense W81XWH-13-1-0134NIDCD NIH HHS T32 DC000011
6 · The paper itself

Abstract

Burgeoning use of segregated microfluidic platforms that parse somas and neurites into discrete compartments is fueling unique examinations of neuronal structure and physiology in a manner impossible to achieve with non-compartmentalized systems. However, even though this line of axon-soma polarizing microfluidic devices stems from the same general design of a Campenot chamber set-up, slight deviations in device geometry appear to induce vastly different nutrient transport profiles that influence neuron survival and maturation. Here we examine the uptake of nerve growth factor (NGF) by a pheochromocytoma PC12 cell line cultured using two Campenot-like device designs, a "Standard" layout, representative of a commercial device, and a custom "Notch" layout, predicted to encourage more efficient nutrient transfer that gives rise to sustained neuron viability and extensive neurite elaboration. Exploiting in vitro culture schemes coupled with computational analyses, we identify the influence of device design geometry on the interplay between neuronal survival and maturation, gauged from morphometric assessments and the spatiotemporal distribution of NGF. Computer simulations of NGF transport within the devices revealed that the microfluidic neuron culture system is highly sensitive to change, where nutrient transport is intricately linked to device geometry and cell plating density, and premature depletion of nutrients is observed if specific design criteria are not met. This study underscores the importance of validating specific device geometries for a particular neuro-based assessment, while showcasing computational modeling as a powerful tool to achieve this goal.

Indexed as

Lab-On-A-Chip DevicesAnimalsCell Culture TechniquesCell DifferentiationCell SurvivalComputer SimulationDiffusionNerve Growth FactorNeuronsPC12 CellsRatsNerve Growth FactorCell viabilityMass transportMicrofluidic devicesNerve growth factor (NGF)Nutrient depletionRat pheochromocytoma PC12 cell line

Identifiers

PMID30885631
PMCPMC6732796

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.