Evidence map›Paper›PMID 30884745›Full record

ArticleSensors (Basel, Switzerland)2019

Magnetometer-Based Drift Correction During Rest inIMU Arm Motion Tracking.

Frieder Wittmann, Olivier Lambercy, Roger Gassert

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Adaptive Lifting Index (Sensors (Basel, Switzerland) · 2024
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Frieder WittmannRehabilitation Engineering Lab, Department of Health Science and Technology, ETH Zurich, 8092 Zurich, Switzerland. friederw@ethz.ch.ORCID 0000-0003-4981-1018
Olivier LambercyRehabilitation Engineering Lab, Department of Health Science and Technology, ETH Zurich, 8092 Zurich, Switzerland. olivier.lambercy@hest.ethz.ch.
Roger GassertRehabilitation Engineering Lab, Department of Health Science and Technology, ETH Zurich, 8092 Zurich, Switzerland. roger.gassert@hest.ethz.ch.ORCID 0000-0002-6373-8518

Funding

ETH Foundation ET-17 13-2Kommission für Technologie und Innovation 13612.1
6 · The paper itself

Abstract

Real-time motion capture of the human arm in the home environment has many usecases, such as video game and therapy applications. The required tracking can be based onoff-the-shelf Inertial Measurement Units (IMUs) with integrated three-axis accelerometers, gyroscopes,and magnetometers. However, this usually requires a homogeneous magnetic field to correctfor orientation drift, which is often not available inside buildings. In this paper, RPMC (RestPose Magnetometer-based drift Correction), a novel method that is robust to long term drift inenvironments with inhomogeneous magnetic fields, is presented. The sensor orientation is estimatedby integrating the angular velocity measured by the gyroscope and correcting drift around the pitchand roll axes with the acceleration information. This commonly leads to short term drift aroundthe gravitational axis. Here, during the calibration phase, the local magnetic field direction for eachsensor, and its orientation relative to the inertial frame, are recorded in a rest pose. It is assumed thatarm movements in free space are exhausting and require regular rest. A set of rules is used to detectwhen the user has returned to the rest pose, to then correct for the drift that has occurred with themagnetometer. Optical validations demonstrated accurate (root mean square error RMS = 6.1), lowlatency (61 ms) tracking of the user's wrist orientation, in real time, for a full hour of arm movements.The reduction in error relative to three alternative methods implemented for comparison was between82.5% and 90.7% for the same movement and environment. Therefore, the proposed arm trackingmethod allows for the correction of orientation drift in an inhomogeneous magnetic field by exploitingthe user's need for frequent rest.

Indexed as

disturbanceinertial trackingMadgwicknon-homogeneousnonhomogeneousperturbationrehabilitationstrokevirtual realitywearable sensors

Identifiers

PMID30884745
PMCPMC6471153

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.