ArticleMagnetic resonance in medicine2019
An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping.
Article in Magnetic resonance in medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Myelin water imaging from accelerated 3D-GRASE acquisitions using subspace constrained reconstruction.Magma (New York, N.Y.) · 2025Article
- Golden-Angle Radial MRI: Basics, Advances, and Applications.Journal of magnetic resonance imaging : JMRI · 2022Review
- A Fetal Brain magnetic resonance Acquisition Numerical phantom (FaBiAN).Scientific reports · 2022Article
- TMagnetic resonance in medicine · 2022Article
- Abdominal T2-Weighted Imaging and T2 Mapping Using a Variable Flip Angle Radial Turbo Spin-Echo Technique.Journal of magnetic resonance imaging : JMRI · 2022Article
- Efficient TMagnetic resonance in medicine · 2021Article
- Magnetization-prepared GRASP MRI for rapid 3D T1 mapping and fat/water-separated T1 mapping.Magnetic resonance in medicine · 2021Article
- Rapid high-resolution volumetric TMagnetic resonance imaging · 2021Article
- A multi-scale residual network for accelerated radial MR parameter mapping.Magnetic resonance imaging · 2020Article
- Quantitative TMagnetic resonance imaging · 2020Article
- Computational MRI with Physics-based Constraints: Application to Multi-contrast and Quantitative Imaging.IEEE signal processing magazine · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
purposeTo design a pulse sequence for efficient 3D T2-weighted imaging and T2 mapping.
methodsA stack-of-stars turbo spin echo pulse sequence with variable refocusing flip angles and a flexible pseudorandom view ordering is proposed for simultaneous T2-weighted imaging and T2 mapping. An analytical framework is introduced for the selection of refocusing flip angles to maximize relative tissue contrast while minimizing T2 estimation errors and maintaining low specific absorption rate. Images at different echo times are generated using a subspace constrained iterative reconstruction algorithm. T2 maps are obtained by modeling the signal evolution using the extended phase graph model. The technique is evaluated using phantoms and demonstrated in vivo for brain, knee, and carotid imaging.
resultsNumerical simulations demonstrate an improved point spread function with the proposed pseudorandom view ordering compared to golden angle view ordering. Phantom experiments show that T2 values estimated from the stack-of-stars turbo spin echo pulse sequence with variable refocusing flip angles have good concordance with spin echo reference values. In vivo results show the proposed pulse sequence can generate qualitatively comparable T2-weighted images as conventional Cartesian 3D SPACE in addition to simultaneously generating 3D T2 maps.
conclusionThe proposed stack-of-stars turbo spin echo pulse sequence with pseudorandom view ordering and variable refocusing flip angles allows high resolution isotropic T2 mapping in clinically acceptable scan times. The optimization framework for the selection of refocusing flip angles improves T2 estimation accuracy while generating T2-weighted contrast comparable to conventional Cartesian imaging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.