Evidence map›Paper›PMID 30883010›Full record

ArticleJournal of applied clinical medical physics2019

Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study.

James Rijken, Hilmar Schachenmayr, Scott Crowe, Tanya Kairn, Jamie Trapp

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Planning and deploying a remote satellite radiotherapy unit: a practical guide for clinicians and health administrators.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2026
    Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 2 countries.

James RijkenGenesisCare, Flinders Private Hospital, Bedford Park, SA, Australia.
Hilmar SchachenmayrGenesisCare, Shenton House, Joondalup, WA, Australia.
Scott CroweQueensland University of Technology, Brisbane, QLD, Australia.
Tanya KairnQueensland University of Technology, Brisbane, QLD, Australia.
Jamie TrappQueensland University of Technology, Brisbane, QLD, Australia.
Royal Brisbane and Women's Hospital · AUFlinders Private Hospital · AUGenesis HealthCare · USQueensland University of Technology · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeBeam matching occurs on all linacs to some degree and when two are more are matched to each other, patients are able to be transferred between machines. Quality assurance of plans can also be performed "distributively" on any of the matched linacs. The degree to which machines are matched and how this translates to like delivery of plans has been the focus of a number of studies. This concept has not yet been explored for stereotactic techniques which require a higher degree of accuracy. This study proposes beam matching criteria which allows for the distributive delivery and quality assurance of stereotactic body radiotherapy (SBRT) plans.

methodTwo clinically relevant and complex volumetric modulated arc therapy (VMAT) SBRT spine and lung plans were chosen as benchmarking cases. These were delivered on nine previously beam matched linacs with quality assurance performed through ArcCheck and film exposure in the sagittal plane. Measured doses were compared to their treatment planning system predictions through gamma analysis at a range of criteria.

resultsDespite differences in beam match parameters and variations in small fields, all nine linacs produced accurate deliveries with a tight deviation in the population sample. Pass rates were well above suggested tolerances at the recommended gamma criterion. Film was able to detect dose errors to a greater degree than ArcCheck.

conclusionDistributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linacs is certainly feasible provided the linacs are matched to a strict protocol like that suggested in this study and regular quality assurance is performed on the matched fleet. Distributive quality assurance and delivery of SBRT provides the possibility of efficiency gains for physicists as well as treatment staff.

Indexed as

Feasibility StudiesHumansLung NeoplasmsOrgans at RiskParticle AcceleratorsQuality Assurance, Health CareRadiosurgeryRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedSpinal NeoplasmsStereotaxic Techniquesbeam matchmatchSBRTspinestereoVMAT

Identifiers

PMID30883010
PMCPMC6448346
OpenAlexW2920888753

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.