Evidence map›Paper›PMID 30875893›Full record

ArticleSensors (Basel, Switzerland)2019

A Novel PZT Pump with Built-in Compliant Structures.

Qibo Bao, Jianhui Zhang, Ming Tang, Zhi Huang, Liyi Lai, Jun Huang, Chuanyu Wu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Qibo BaoCollege of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China. 2111707005@e.gzhu.edu.cn.
Jianhui ZhangCollege of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China. zhangjh@nuaa.edu.cn.
Ming TangCollege of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China. 2111707033@e.gzhu.edu.cn.
Zhi HuangCollege of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China. 2111807019@e.gzhu.edu.cn.
Liyi LaiCollege of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China. 2111807002@e.gzhu.edu.cn.
Jun HuangNational Research Center of Pumps, Jiangsu University, Zhenjiang 212013, China. huangjun@ujs.edu.cn.ORCID 0000-0003-4126-681X
Chuanyu WuFaculty of Mechanical Engineering & Automation, Zhejiang Sci-Tech University, Hangzhou 310018, China. cywu@zstu.edu.cn.

Funding

Graduate-Ability-Promotion Plan of Guangzhou University 2111707005National Natural Science Foundation of China 51375227
6 · The paper itself

Abstract

Different to the traditionally defined valved piezoelectric (PZT) pump and valveless PZT pump, two groups of PZT pumps with built-in compliant structures-with distances between the free ends of 0.2 mm (Group A) and 0 mm (Group B)-were designed, fabricated, and experimentally tested. This type of pump mainly contains a chamber 12 mm in diameter and 1.1 mm in height, a PZT vibrator, and two pairs of compliant structures arranged on the flowing channel. The flow-resistance differences between these two groups of PZT pumps were theoretically and experimentally verified. The relationships between the amplitude, applied voltage and frequency of the PZT vibrators were obtained experimentally, with results illustrating that the amplitude linearly and positively correlates with the voltage, while nonlinearly and negatively correlating to the frequency. The flow rate performance of these two groups was experimentally tested from 110⁻160 Vpp and 10⁻130 Hz. Results showed that the flow rate positively correlates to the voltage, and the optimum flow rate frequency centers around 90 Hz for Group A and 80 Hz for Group B, respectively. The flow rate performances of Group B were further measured from 60⁻100 Hz and 170⁻210 Vpp, and obtained optimal flow rates of 3.6 mL/min at 210 Vpp and 80 Hz when ignoring the siphon-caused backward flow rate. As the compliant structures are not prominently limited by the channel's size, and the pump can be minimized by Micro-electromechanical Systems (MEMS) processing methods, it is a suitable candidate for microfluidic applications like closed-loop cooling systems and drug delivery systems.

Indexed as

Compliant structuresflow ratePZT pumpvalved pumpvalveless pump

Identifiers

PMID30875893
PMCPMC6471629

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.