ArticlePloS one2019
Deformable registration of 3D ultrasound volumes using automatic landmark generation.
Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 4 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
US image registration is an important task e.g. in Computer Aided Surgery. Due to tissue deformation occurring between pre-operative and interventional images often deformable registration is necessary. We present a registration method focused on surface structures (i.e. saliencies) of soft tissues like organ capsules or vessels. The main concept follows the idea of representative landmarks (so called leading points). These landmarks represent saliencies in each image in a certain region of interest. The determination of deformation was based on a geometric model assuming that saliencies could locally be described by planes. These planes were calculated from the landmarks using two dimensional linear regression. Once corresponding regions in both images were found, a displacement vector field representing the local deformation was computed. Finally, the deformed image was warped to match the pre-operative image. For error calculation we used a phantom representing the urinary bladder and the prostate. The phantom could be deformed to mimic tissue deformation. Error calculation was done using corresponding landmarks in both images. The resulting target registration error of this procedure amounted to 1.63 mm. With respect to patient data a full deformable registration was performed on two 3D-US images of the abdomen. The resulting mean distance error was 2.10 ± 0.66 mm compared to an error of 2.75 ± 0.57 mm from a simple rigid registration. A two-sided paired t-test showed a p-value < 0.001. We conclude that the method improves the results of the rigid registration considerably. Provided an appropriate choice of the filter there are many possible fields of applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.