Evidence map›Paper›PMID 30874980›Full record

ArticleThe international journal of cardiovascular imaging2019

Early vessel healing after implantation of biodegradable-polymer and durable-polymer drug-eluting stent: 3-month angioscopic evaluation of the RESTORE registry.

Satoshi Suzuki, Yohei Sotomi, Tomoaki Kobayashi, Yuma Hamanaka, Shimpei Nakatani, Ichiro Shiojima, Yasushi Sakata, Atsushi Hirayama, Yoshiharu Higuchi

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Observational
  3. Article
  4. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Satoshi SuzukiDepartment of Cardiology, Osaka Police Hospital, 10-31, Kitayama, Tennoji, 543-0035, Osaka, Japan.
Yohei SotomiDepartment of Cardiology, Osaka Police Hospital, 10-31, Kitayama, Tennoji, 543-0035, Osaka, Japan. sotomiyohei@gmail.com.
Tomoaki KobayashiDepartment of Cardiology, Osaka Police Hospital, 10-31, Kitayama, Tennoji, 543-0035, Osaka, Japan.
Yuma HamanakaDepartment of Cardiology, Osaka Police Hospital, 10-31, Kitayama, Tennoji, 543-0035, Osaka, Japan.
Shimpei NakataniDepartment of Cardiology, Osaka Police Hospital, 10-31, Kitayama, Tennoji, 543-0035, Osaka, Japan.
Ichiro ShiojimaDepartment of Medicine II, Kansai Medical University, Hirakata, Japan.
Yasushi SakataDepartment of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Osaka, Japan.
Atsushi HirayamaDepartment of Cardiology, Osaka Police Hospital, 10-31, Kitayama, Tennoji, 543-0035, Osaka, Japan.
Yoshiharu HiguchiDepartment of Cardiology, Osaka Police Hospital, 10-31, Kitayama, Tennoji, 543-0035, Osaka, Japan.
Osaka Police Hospital · JPKansai Medical University · JPOsaka University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study was to evaluate the vessel healing status 3 months after stent implantation of bioresorbable-polymer drug-eluting stents (BP-DESs) in comparison with durable-polymer DESs (DP-DESs) by angioscopy. Study design was a single-center all-comer prospective cohort study: the RESTORE registry (UMIN000033009). All patients who received successful angioscopic examination at planned 3-month follow-up after the DES implantation in the native coronary artery were enrolled. We evaluated main, maximum, minimum strut coverage grades and coverage heterogeneity score defined as a difference between maximum and minimum coverage grades. All lesions were divided into three segments: proximal, mid, and distal segments. A total of 108 patients (66.6 ± 10 years) with 124 lesions were analyzed (BP-DES 57 patients 61 lesions 226 segments vs. DP-DES 57 patients 63 lesions 203 segments; six patients had both BP-DES and DP-DES). Patient and lesion demographics, procedural characteristics were well balanced. Main coverage grade (mean ± standard error; 1.08 ± 0.02 vs. 1.05 ± 0.03, p = 0.354) and minimum coverage grade (1.00 ± 0.00 vs. 1.00 ± 0.00, p > 0.999) were not significantly different between BP-DES and DP-DES groups. Maximum coverage grade was significantly higher in the BP-DES than in the DP-DES (1.45 ± 0.04 vs. 1.35 ± 0.04, p = 0.049). Coverage heterogeneity score did not differ between BP-DES and DP-DES groups (1.05 ± 0.07 vs. 0.90 ± 0.07, p = 0.162). At 3-month follow-up, the current BP-DES had higher maximum stent coverage than the contemporary DP-DES, while main and minimum coverage grades and heterogeneity of the neointimal coverage were comparable. Further prospective randomized trials should be conducted to evaluate the clinical significance of the present imaging results.

Indexed as

Absorbable ImplantsAngioscopyDrug-Eluting StentsWound HealingAgedCoronary Artery DiseaseCoronary VesselsFemaleHumansJapanMaleMiddle AgedNeointimaPercutaneous Coronary InterventionPlaque, AtheroscleroticPolymersPolymersBiodegradable polymerCoronary angioscopyDrug-eluting stentDurable polymer

Identifiers

PMID30874980
OpenAlexW2922094193

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.