Evidence map›Paper›PMID 30871288›Full record

ArticleKnee surgery & related research2019

The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty.

Kwangkyoun Kim, Jungsung Kim, Dokyoung Lee, Sohui Lim, Jiyoon Eom

Open access · diamondAbstract read
In one paragraph

Article in Knee surgery & related research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
3.8field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 21 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. A single type of varus knee does not exist: morphotyping and gap analysis in varus OA.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022
    Article
  10. Article
  11. Distal femoral phenotypes in Asian varus osteoarthritic knees.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022
    Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Kwangkyoun KimDepartments of Orthopedic Surgery.
Jungsung KimMedical Engineering, Konyang University College of Medicine, Daejeon, Korea.
Dokyoung LeeDepartments of Orthopedic Surgery.
Sohui LimMedical Engineering, Konyang University College of Medicine, Daejeon, Korea.
Jiyoon EomMedical Engineering, Konyang University College of Medicine, Daejeon, Korea.
Konyang University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study is to assess the accuracy of alignment determined by patient-specific instrumentation system in total knee arthroplasty(TKA). MATERIALS AND

methodsTwenty-seven TKAs using patient-specific instrument were reviewed. The intraoperative pin location determined by the patient-specific guide was recorded using imageless navigation software. Data recorded included tibial coronal alignment and posterior slope, femoral coronal alignment and sagittal alignment, and transepicondylar axis. A discrepancy within ±3° in each plane was considered an acceptable result.

resultsOn the tibia, an acceptable alignment was obtained in 24 (88.1%) in the coronal plane and 21 (77.8%) in the sagittal plane. On the femur, a satisfactory alignment was obtained in 25 (92.6%) in the coronal plane and 24 (88.1%) in the sagittal plane. Based on the transepicondylar axis, a satisfactory alignment was obtained in 23 (85.1%).

conclusionsSatisfactory alignment was obtained in more than 85% of each plane of the femur and in the coronal plane of the tibia and relative to the transepicondylar axis. Sufficeint experience and precise preoperative planning are required to improve the accuracy of sagittal alignment of the tibia.

Indexed as

ArthroplastyComputer assistedKneePatient specific instrument

Identifiers

PMID30871288
PMCPMC6425897
OpenAlexW2921629452

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.