Evidence map›Paper›PMID 30871284›Full record

ArticleMicromachines2019

Sub-ppb Level Detection of BTEX Gaseous Mixtures with a Compact Prototype GC Equipped with a Preconcentration Unit.

Irene Lara-Lbeas, Alberto Rodríguez-Cuevas, Christina Andrikopoulou, Vincent Person, Lucien Baldas, Stéphane Colin, Stéphane Le Calvé

Abstract read
In one paragraph

Article in Micromachines, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Irene Lara-LbeasICPEES UMR 7515, Université de Strasbourg/CNRS, F-67000 Strasbourg, France. ilaraibeas@unistra.fr.
Alberto Rodríguez-CuevasIn'Air Solutions, 25 rue Becquerel, 67087 Strasbourg, France. arodriguez@inairsolutions.com.
Christina AndrikopoulouICPEES UMR 7515, Université de Strasbourg/CNRS, F-67000 Strasbourg, France. candrikopoulou@unistra.fr.
Vincent PersonIn'Air Solutions, 25 rue Becquerel, 67087 Strasbourg, France. vperson@inairsolutions.fr.
Lucien BaldasInstitut Clément Ader (ICA), Université de Toulouse/CNRS, INSA, ISAE-SUPAERO, Mines-Albi, UPS, 31400 Toulouse, France. baldas@insa-toulouse.fr.
Stéphane ColinInstitut Clément Ader (ICA), Université de Toulouse/CNRS, INSA, ISAE-SUPAERO, Mines-Albi, UPS, 31400 Toulouse, France. stephane.colin@insa-toulouse.fr.
Stéphane Le CalvéICPEES UMR 7515, Université de Strasbourg/CNRS, F-67000 Strasbourg, France. slecalve@unistra.fr.

Funding

Clean Sky 2 Joint Undertaking under the European Union's Horizon 2020 research and innovation program 687014ELCOD project which was implemented as a part of the INTERREG V Oberrhein/Rhin Supérieur program and was supported by the European Regional Development Fund (ERDF) and the co-financed project partners Region Grand Est in France and the countries of Baden- ELCODEuropean Commission 643095
6 · The paper itself

Abstract

In this work, a compact gas chromatograph prototype for near real-time benzene, toluene, ethylbenzene and xylenes (BTEX) detection at sub-ppb levels has been developed. The system is composed of an aluminium preconcentrator (PC) filled with Basolite C300, a 20 m long Rxi-624 capillary column and a photoionization detector. The performance of the device has been evaluated in terms of adsorption capacity, linearity and sensitivity. Initially, PC breakthrough time for an equimolar 1 ppm BTEX mixture has been determined showing a remarkable capacity of the adsorbent to quantitatively trap BTEX even at high concentrations. Then, a highly linear relationship between sample volume and peak area has been obtained for all compounds by injecting 100-ppb samples with volumes ranging from 5⁻80 mL. Linear plots were also observed when calibration was conducted in the range 0⁻100 ppb using a 20 mL sampling volume implying a total analysis time of 19 min. Corresponding detection limits of 0.20, 0.26, 0.49, 0.80 and 1.70 ppb have been determined for benzene, toluene, ethylbenzene, m/p-xylenes and o-xylene, respectively. These experimental results highlight the potential applications of our device to monitor indoor or outdoor air quality.

Indexed as

BTEXmicrofluidicsminiaturized gas chromatographPID detectorpreconcentrator

Identifiers

PMID30871284
PMCPMC6470503

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.