Evidence map›Paper›PMID 30868804›Full record

ArticleJournal of biomedical optics2019

Real-time, wide-field, and quantitative oxygenation imaging using spatiotemporal modulation of light.

Manon Schmidt, Enagnon Aguénounon, Amir Nahas, Murielle Torregrossa, Bruce J Tromberg, Wilfried Uhring, Sylvain Gioux

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Manon SchmidtUniversity of Strasbourg, ICube Laboratory, Strasbourg, France.
Enagnon AguénounonUniversity of Strasbourg, ICube Laboratory, Strasbourg, France.
Amir NahasUniversity of Strasbourg, ICube Laboratory, Strasbourg, France.
Murielle TorregrossaUniversity of Strasbourg, ICube Laboratory, Strasbourg, France.
Bruce J TrombergBeckman Laser Institute and Medical Clinic, Laser Microbeam and Medical Program, Irvine, California, United States.
Wilfried UhringUniversity of Strasbourg, ICube Laboratory, Strasbourg, France.
Sylvain GiouxUniversity of Strasbourg, ICube Laboratory, Strasbourg, France.
Laboratoire des Sciences de l'Ingénieur, de l'Informatique et de l'Imagerie · FRUniversity of California, Irvine · US

Funding

European Research Council
6 · The paper itself

Abstract

Quantitative diffuse optical imaging has the potential to provide valuable functional information about tissue status, such as oxygen saturation or blood content to healthcare practitioners in real time. However, significant technical challenges have so far prevented such tools from being deployed in the clinic. Toward achieving this goal, prior research introduced methods based on spatial frequency domain imaging (SFDI) that allow real-time (within milliseconds) wide-field imaging of optical properties but at a single wavelength. However, for this technology to be useful to clinicians, images must be displayed in terms of metrics related to the physiological state of the tissue, hence interpretable to guide decision-making. For this purpose, recent developments introduced multispectral SFDI methods for rapid imaging of oxygenation parameters up to 16 frames per seconds (fps). We introduce real-time, wide-field, and quantitative blood parameters imaging using spatiotemporal modulation of light. Using this method, we are able to quantitatively obtain optical properties at 100 fps at two wavelengths (665 and 860 nm), and therefore oxygenation, oxyhemoglobin, and deoxyhemoglobin, using a single camera with, at most, 4.2% error in comparison with standard SFDI acquisitions.

Indexed as

HandHemoglobinsHumansImage Processing, Computer-AssistedOptical ImagingOxygenOxyhemoglobinsPhantoms, ImagingdeoxyhemoglobinHemoglobinsOxygenOxyhemoglobinsdiffuse optical imagingoxygenation imagingspatial frequency domain imaging

Identifiers

PMID30868804
PMCPMC6995963
OpenAlexW2922277132

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.