Evidence map›Paper›PMID 30861308›Full record

ArticleJournal of applied clinical medical physics2019

Evaluation of mixed energy partial arcs for volumetric modulated arc therapy for prostate cancer.

Shadab Momin, James L Gräfe, Rao F Khan

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Shadab MominDepartment of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, USA.
James L GräfeDepartment of Physics, Ryerson University, Toronto, ON, Canada.
Rao F KhanDepartment of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, USA.
Washington University in St. Louis · USToronto Metropolitan University · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this work was to investigate the dosimetric impact of mixed energy (6-MV, 15-MV) partial arcs (MEPAs) technique on prostate cancer VMAT plans.

methodsThis work involved prostate only patients, planned with 79.2 Gy in 44 fractions to the planning target volume (PTV). Femoral heads, bladder, and rectum were considered organs at risk. This study was performed in two parts. For each of the 25 patients in Part 1, two single-energy single-arc plans, a 6 MV-SA plan and a 15 MV-SA plan, and a third MEPA plan involving composite of 6-MV anterior-posterior partial arcs and a 15-MV lateral partial arc weighted 1:2 were created. The dosimetric difference between MEPA(6/15 MV 1:2 weighted) and 6 MV-SA plans, and MEPA(6/15 MV 1:2 weighted) and 15 MV-SA plans were measured. In the Part 2 of this study, a second MEPAs plan (6 MV anterior-posterior arcs and 15 MV lateral arcs weighted 1:1), (MEPA 6/15 MV 1:1 weighted), was generated for 15 patients and compared only with two single-energy partial arcs plans, a 6 and a 15 MV-PA, to investigate the influence of the energy only. Dosimetric parameters of each structure, total monitor-units (MUs), homogeneity index (HI), and conformity number (CN) were analyzed.

resultsIn Part 1, no statistically significant differences were observed for mean dose to PTV and CN for MEPAs (6/15 MV 1:2 weighted) vs 6 and 15 MV-SA. MEPAs (6/15 MV 1:2 weighted) increased HI compared to 6 and 15 MV-SA (P < 0.0005; P < 0.0005). MEPAs (6/15 MV 1:2 weighted) produced significantly lower mean doses to rectum, bladder, and MUs/fraction, but higher mean doses to femoral heads, compared to 6 MV-SA (P < 0.0005) and 15 MV-SA (P < 0.0005). The results of Part 2 of this study showed that, in comparison to 6 and 15 MV-PA, MEPAs (6/15 MV 1:1 weighted) plans significantly improved CNs (P < 0.0005; P < 0.0005) and produced significantly lower mean doses to the rectum and bladder (P < 0.0005; P < 0.0005). While mean doses to the PTV and femoral heads of MEPAs (6/15 MV 1:1 weighted) plans were statistically comparable to 6 MV-PA (P > 0.05), MEPAs (6/15 MV 1:1 weighted) increased mean doses to left (P = 0.04) and right (P = 0.04) femoral heads compared to 15 MV-PA. MEPAs (6/15 MV 1:1 weighted) resulted in significantly lower total MUs compared to 6 MV-PA (P < 0.0005) and 15 MV-PA (P = 0.04).

conclusionThe study for prostate radiotherapy demonstrated that a choice of MEPAs for VMAT has the potential to minimize doses to OARs and improve dose conformity to PTV, at the expense of a moderate increase in mean dose to the femoral heads.

Indexed as

AgedHumansMaleOrgans at RiskPrognosisProstatic NeoplasmsRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-Assistedmixed energy VMAToptimizationtreatment planning

Identifiers

PMID30861308
PMCPMC6448169
OpenAlexW2922380497

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked