Evidence map›Paper›PMID 30859457›Full record

ArticleInternational journal of computer assisted radiology and surgery2019

Unifying the seeds auto-generation (SAGE) with knee cartilage segmentation framework: data from the osteoarthritis initiative.

Hong-Seng Gan, Khairil Amir Sayuti, Muhammad Hanif Ramlee, Yeng-Seng Lee, Wan Mahani Hafizah Wan Mahmud, Ahmad Helmy Abdul Karim

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hong-Seng GanMedical Engineering Technology Section, Universiti Kuala Lumpur, British Malaysian Institute, Bt 8, Jln Sg Pusu, 53100, Gombak, Selangor, Malaysia. hongseng@unikl.edu.my.ORCID http://orcid.org/0000-0003-3777-3640
Khairil Amir SayutiDepartment of Radiology, School of Medical Science, Universiti Sains Malaysia, 16150, Kubang Kerian, Kelantan, Malaysia.
Muhammad Hanif RamleeMedical Devices and Technology Group (MEDITEG), Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia.
Yeng-Seng LeeDepartment of Electronic Engineering Technology, Faculty of Engineering Technology, Universiti Malaysia Perlis, 02600, Arau, Perlis, Malaysia.
Wan Mahani Hafizah Wan MahmudDepartment of Electronic Engineering, Faculty of Electrical and Electronic Engineering, Universiti Tun Hussein Onn Malaysia, 86400, Batu Pahat, Johor, Malaysia.
Ahmad Helmy Abdul KarimDiagnostic Imaging Services, KPJ Ipoh Specialist Hospital, 30350, Ipoh, Perak, Malaysia.

Funding

Malaysian Ministry of Higher Education FRGS/1/2018/ICT02/UNIKL/02/4Unit Penyelidikan & Inovasi MARA MARA/UNI:1/33/18/18(1)
6 · The paper itself

Abstract

purposeManual segmentation is sensitive to operator bias, while semiautomatic random walks segmentation offers an intuitive approach to understand the user knowledge at the expense of large amount of user input. In this paper, we propose a novel random walks seed auto-generation (SAGE) hybrid model that is robust to interobserver error and intensive user intervention.

methodsKnee image is first oversegmented to produce homogeneous superpixels. Then, a ranking model is developed to rank the superpixels according to their affinities to standard priors, wherein background superpixels would have lower ranking values. Finally, seed labels are generated on the background superpixel using Fuzzy C-Means method.

resultsSAGE has achieved better interobserver DSCs of 0.94 ± 0.029 and 0.93 ± 0.035 in healthy and OA knee segmentation, respectively. Good segmentation performance has been reported in femoral (Healthy: 0.94 ± 0.036 and OA: 0.93 ± 0.034), tibial (Healthy: 0.91 ± 0.079 and OA: 0.88 ± 0.095) and patellar (Healthy: 0.88 ± 0.10 and OA: 0.84 ± 0.094) cartilage segmentation. Besides, SAGE has demonstrated greater mean readers' time of 80 ± 19 s and 80 ± 27 s in healthy and OA knee segmentation, respectively.

conclusionsSAGE enhances the efficiency of segmentation process and attains satisfactory segmentation performance compared to manual and random walks segmentation. Future works should validate SAGE on progressive image data cohort using OA biomarkers.

Indexed as

AlgorithmsCartilage, ArticularFemurHumansKnee JointMagnetic Resonance ImagingOsteoarthritis, KneeReproducibility of ResultsTibiaAutomaticKnee cartilage segmentationRandom walksSeeds

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.