Evidence map›Paper›PMID 30848845›Full record

ArticleNeurourology and urodynamics2019

Outcome and complications of adjustable continence therapy (ProACT

Toscane C Noordhoff, Enrico Finazzi-Agrò, Jeroen R Scheepe, Bertil F M Blok

Abstract readMulticenter Study
In one paragraph

Article in Neurourology and urodynamics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Adjustable continence therapy (ProACT/ACTTranslational andrology and urology · 2024
    Review
  2. Review
  3. Dual balloon adjustable continence therapy for urinary incontinence.American journal of clinical and experimental urology · 2023
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Toscane C NoordhoffDepartment of Urology, Erasmus University Medical Center, Rotterdam, The Netherlands.ORCID 0000-0002-7508-0215
Enrico Finazzi-AgròDepartment of Eperimental Medicine and Surgery, University of Rome "Tor Vergata", Urology Unit, Policlinico Tor Vergata, Rome, Italy.
Jeroen R ScheepeDepartment of Urology, Erasmus University Medical Center, Rotterdam, The Netherlands.
Bertil F M BlokDepartment of Urology, Erasmus University Medical Center, Rotterdam, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo evaluate the outcome of adjustable continence balloons in the treatment of stress urinary incontinence (SUI) after transurethral resection of the prostate (TURP).

methodsIn two tertiary centers, adjustable continence balloons were implanted in 29 patients with post-TURP SUI between 2007 and 2018. Endpoints of this retrospective multicenter study were patient-reported changes in pad count and complications. Dry was defined as no pad or one security pad.

resultsPreoperative urinary incontinence was mild in 7 (24%), moderate in 12 (41%), and severe in 10 (35%) patients. The median follow-up duration was 21 (interquartile range [IQR], 11-43) months. Within 30 days postoperatively, a Clavien-Dindo grade less than or equal to II complication occurred in 24% of the patients. Reintervention rate was 24%. Six and 12 months after implantation, the International Prostate Symptom Score (IPSS) quality-of-life item improved significantly from 5 (IQR, 5-6) preoperatively to 3 (IQR, 1-4.5) and 1 (IQR, 0-3), respectively. At last visit (median 21 months after implantation), the outcome on continence had improved in 76% of the patients, including, 45% dry patients. After a median follow-up of 28 months (IQR, 13-63; N = 23), all but one patient reported improvement on the Patient Global Impression of Improvement (PGI-I) scale. In detail, 10 patients reported "very much better" condition compared with before the implantation, 10 patients "much better," two patients "a little better," and one patient "no change." Daily pad use decreased from three (IQR, 2-5) to one (IQR, 0-2) pads/day (P < 0.001).

conclusionsThis is hitherto, the first study reporting results of adjustable continence balloons in the treatment of post-TURP SUI. The therapy was found to be safe and efficient. The majority of our study population reported improvement on their condition and greater than or equal to 50% reduction in daily pad use.

Indexed as

Quality of LifeAgedBalloon OcclusionHumansIncontinence PadsMaleMiddle AgedProstateProstatectomyRetrospective StudiesTransurethral Resection of ProstateTreatment OutcomeUrinary Incontinenceminimally invasive surgical procedurespersonal satisfactionpostoperative complicationsstress urinary incontinencetransurethral resection of prostate

Identifiers

PMID30848845
PMCPMC6850145