Evidence map›Paper›PMID 30845203›Full record

ArticlePloS one2019

Comparative performance of four rapid Ebola antigen-detection lateral flow immunoassays during the 2014-2016 Ebola epidemic in West Africa.

Betsy Wonderly, Sophie Jones, Michelle L Gatton, John Barber, Marian Killip, Chris Hudson, Lisa Carter, Tim Brooks, Andrew J H Simpson, Amanda Semper and 4 more

Open access · goldAbstract readComparative Study
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
4.2field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it, 48 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Diagnostics of Ebola virus.Frontiers in public health · 2023
    Review
  5. Article
  6. Article
  7. Thermally Responsive Alkane Partitions for Assay Automation.ACS applied materials & interfaces · 2022
    Article
  8. Rapid detection of SARS-CoV-2: The gradual boom of lateral flow immunoassay.Frontiers in bioengineering and biotechnology · 2022
    Review
  9. Review
  10. Review
  11. Article
  12. Ebola Virus Disease and Current Therapeutic Strategies: A Review.Advances in experimental medicine and biology · 2021
    Review
  13. Article
  14. Review
  15. Review-Chemical and Biological Sensors for Viral Detection.Journal of the Electrochemical Society · 2020
    Article
  16. Review
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 5 institutions in 3 countries.

Betsy WonderlyFoundation for Innovative New Diagnostics (FIND), Geneva, Switzerland.
Sophie JonesFoundation for Innovative New Diagnostics (FIND), Geneva, Switzerland.
Michelle L GattonSchool of Public Health and Social Work, Queensland University of Technology, Brisbane, Australia.
John BarberFoundation for Innovative New Diagnostics (FIND), Geneva, Switzerland.
Marian KillipFoundation for Innovative New Diagnostics (FIND), Geneva, Switzerland.
Chris HudsonFoundation for Innovative New Diagnostics (FIND), Geneva, Switzerland.
Lisa CarterFoundation for Innovative New Diagnostics (FIND), Geneva, Switzerland.
Tim BrooksPublic Health England, Porton Down, United Kingdom.
Andrew J H SimpsonPublic Health England, Porton Down, United Kingdom.
Amanda SemperPublic Health England, Porton Down, United Kingdom.
Willy UrassaWorld Health Organization, Geneva, Switzerland.
Arlene ChuaMédecins Sans Frontières International, Geneva, Switzerland.
Mark PerkinsFoundation for Innovative New Diagnostics (FIND), Geneva, Switzerland.
Catharina BoehmeFoundation for Innovative New Diagnostics (FIND), Geneva, Switzerland.ORCID 0000-0002-2200-8674
FIND · CHPublic Health England · GBMédecins Sans Frontières · CHQueensland University of Technology · AUWorld Health Organization · CH

Funding

World Health Organization 001
6 · The paper itself

Abstract

backgroundWithout an effective vaccine, as was the case early in the 2014-2016 Ebola Outbreak in West Africa, disease control depends entirely on interrupting transmission through early disease detection and prompt patient isolation. Lateral Flow Immunoassays (LFI) are a potential supplement to centralized reference laboratory testing for the early diagnosis of Ebola Virus Disease (EVD). The goal of this study was to assess the performance of commercially available simple and rapid antigen detection LFIs, submitted for review to the WHO via the Emergency Use Assessment and Listing procedure. The study was performed in an Ebola Treatment Centre laboratory involved in EVD testing in Sierra Leone. In light of the current Ebola outbreak in May 2018 in the Democratic Republic of Congo, which highlights the lack of clarity in the global health community about appropriate Ebola diagnostics, our findings are increasingly critical.

methodsA cross-sectional study was conducted to assess comparative performance of four LFIs for detecting EVD. LFIs were assessed against the same 328 plasma samples and 100 whole EDTA blood samples, using the altona RealStar Filovirus Screen real-time RT-PCR as the bench mark assay. The performance of the Public Health England (PHE) in-house Zaire ebolavirus-specific real time RT-PCR Trombley assay was concurrently assessed. Statistical analysis using generalized estimating equations was conducted to compare LFI performance.

findingsSensitivity and specificity varied between the LFIs, with specificity found to be significantly higher for whole EDTA blood samples compared to plasma samples in at least 2 LFIs (P≤0.003). Using the altona RT-PCR assay as the bench mark, sensitivities on plasma samples ranged from 79.53% (101/127, 95% CI: 71.46-86.17%) for the DEDIATEST EBOLA (SD Biosensor) to 98.43% (125/127, 95% CI: 94.43-99.81%) for the One step Ebola test (Intec). Specificities ranged from 80.20% (158/197, 95% CI: 74.07-88.60%) for plasma samples using the ReEBOV Antigen test Kit (Corgenix) to 100.00% (98/98, 95% CI: 96.31-100.00%) for whole blood samples using the DEDIATEST EBOLA (SD Biosensor) and SD Ebola Zaire Ag (SD Biosensor). Results also showed the Trombley RT-PCR assay had a lower limit of detection than the altona assay, with some LFIs having higher sensitivity than the altona assay when the Trombley assay was the bench mark.

interpretationAll of the tested EVD LFIs may be considered suitable for use in an outbreak situation (i.e. rule out testing in communities), although they had variable performance characteristics, with none possessing both high sensitivity and specificity. The non-commercial Trombley Zaire ebolavirus RT-PCR assay warrants further investigation, as it appeared more sensitive than the current gold standard, the altona Filovirus Screen RT-PCR assay.

Indexed as

AdultAntigens, ViralCross-Sectional StudiesDisease OutbreaksEbolavirusEpidemicsFemaleHemorrhagic Fever, EbolaHumansImmunoassayImmunologic TestsMalePoint-of-Care SystemsReagent Kits, DiagnosticRNA, ViralSensitivity and SpecificityAntigens, ViralReagent Kits, DiagnosticRNA, Viral

Identifiers

PMID30845203
PMCPMC6405069
OpenAlexW2921096282

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.