ArticlePloS one2019
Comparative performance of four rapid Ebola antigen-detection lateral flow immunoassays during the 2014-2016 Ebola epidemic in West Africa.
Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 1 synthesis or guideline pooled it, 48 citations in OpenAlex.
- Rapid diagnostic tests versus RT-PCR for Ebola virus infections: a systematic review and meta-analysis.Bulletin of the World Health Organization · 2022Pooled it
- Development and Clinical Evaluation of a Rapid Point of Care Test for Ebola Virus Infection in Humans.Viruses · 2023Article
- Article
- Diagnostics of Ebola virus.Frontiers in public health · 2023Review
- Perceptions and priorities for the development of multiplex rapid diagnostic tests for acute non-malarial fever in rural South and Southeast Asia: An international modified e-Delphi survey.PLoS neglected tropical diseases · 2022Article
- End-Functionalized Poly(vinylpyrrolidone) for Ligand Display in Lateral Flow Device Test Lines.ACS polymers Au · 2022Article
- Thermally Responsive Alkane Partitions for Assay Automation.ACS applied materials & interfaces · 2022Article
- Rapid detection of SARS-CoV-2: The gradual boom of lateral flow immunoassay.Frontiers in bioengineering and biotechnology · 2022Review
- Nanotechnology-Based Strategies for Effective and Rapid Detection of SARS-CoV-2.Materials (Basel, Switzerland) · 2021Review
- Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives.Sensors (Basel, Switzerland) · 2021Review
- Ultrasensitive point-of-care immunoassay for secreted glycoprotein detects Ebola infection earlier than PCR.Science translational medicine · 2021Article
- Ebola Virus Disease and Current Therapeutic Strategies: A Review.Advances in experimental medicine and biology · 2021Review
- Highly Sensitive Fluorescence-Linked Immunosorbent Assay for the Determination of Human IgG in Serum Using Quantum Dot Nanobeads and Magnetic FeACS omega · 2020Article
- Six decades of lateral flow immunoassay: from determining metabolic markers to diagnosing COVID-19.AIMS microbiology · 2020Review
- Review-Chemical and Biological Sensors for Viral Detection.Journal of the Electrochemical Society · 2020Article
- Forty-two years of responding to Ebola virus outbreaks in Sub-Saharan Africa: a review.BMJ global health · 2020Review
- Characterization and analytical validation of a new antigenic rapid diagnostic test for Ebola virus disease detection.PLoS neglected tropical diseases · 2020Article
- A review of the WHO malaria rapid diagnostic test product testing programme (2008-2018): performance, procurement and policy.Malaria journal · 2019Review
- Article
- Diagnostics for filovirus detection: impact of recent outbreaks on the diagnostic landscape.BMJ global health · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 5 institutions in 3 countries.
Funding
Abstract
backgroundWithout an effective vaccine, as was the case early in the 2014-2016 Ebola Outbreak in West Africa, disease control depends entirely on interrupting transmission through early disease detection and prompt patient isolation. Lateral Flow Immunoassays (LFI) are a potential supplement to centralized reference laboratory testing for the early diagnosis of Ebola Virus Disease (EVD). The goal of this study was to assess the performance of commercially available simple and rapid antigen detection LFIs, submitted for review to the WHO via the Emergency Use Assessment and Listing procedure. The study was performed in an Ebola Treatment Centre laboratory involved in EVD testing in Sierra Leone. In light of the current Ebola outbreak in May 2018 in the Democratic Republic of Congo, which highlights the lack of clarity in the global health community about appropriate Ebola diagnostics, our findings are increasingly critical.
methodsA cross-sectional study was conducted to assess comparative performance of four LFIs for detecting EVD. LFIs were assessed against the same 328 plasma samples and 100 whole EDTA blood samples, using the altona RealStar Filovirus Screen real-time RT-PCR as the bench mark assay. The performance of the Public Health England (PHE) in-house Zaire ebolavirus-specific real time RT-PCR Trombley assay was concurrently assessed. Statistical analysis using generalized estimating equations was conducted to compare LFI performance.
findingsSensitivity and specificity varied between the LFIs, with specificity found to be significantly higher for whole EDTA blood samples compared to plasma samples in at least 2 LFIs (P≤0.003). Using the altona RT-PCR assay as the bench mark, sensitivities on plasma samples ranged from 79.53% (101/127, 95% CI: 71.46-86.17%) for the DEDIATEST EBOLA (SD Biosensor) to 98.43% (125/127, 95% CI: 94.43-99.81%) for the One step Ebola test (Intec). Specificities ranged from 80.20% (158/197, 95% CI: 74.07-88.60%) for plasma samples using the ReEBOV Antigen test Kit (Corgenix) to 100.00% (98/98, 95% CI: 96.31-100.00%) for whole blood samples using the DEDIATEST EBOLA (SD Biosensor) and SD Ebola Zaire Ag (SD Biosensor). Results also showed the Trombley RT-PCR assay had a lower limit of detection than the altona assay, with some LFIs having higher sensitivity than the altona assay when the Trombley assay was the bench mark.
interpretationAll of the tested EVD LFIs may be considered suitable for use in an outbreak situation (i.e. rule out testing in communities), although they had variable performance characteristics, with none possessing both high sensitivity and specificity. The non-commercial Trombley Zaire ebolavirus RT-PCR assay warrants further investigation, as it appeared more sensitive than the current gold standard, the altona Filovirus Screen RT-PCR assay.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.