Evidence map›Paper›PMID 30843867›Full record

ArticleJMIR mHealth and uHealth2019

See-Through Type 3D Head-Mounted Display-Based Surgical Microscope System for Microsurgery: A Feasibility Study.

Cheol-Hwan Kim, Seon-Young Ryu, Ji-Young Yoon, Hyoung-Kwon Lee, Nak-Gu Choi, Il-Ho Park, Hae-Young Choi

Open access · goldAbstract read
In one paragraph

Article in JMIR mHealth and uHealth, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 11 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Cheol-Hwan Kim *Institute of Advanced Convergence Technology, Kyungpook National University, Daegu, Republic of Korea.ORCID 0000-0002-5591-4147
Seon-Young Ryu *Department of Creative IT Engineering, Pohang University of Science and Technology, Pohang, Republic of Korea.ORCID 0000-0002-7594-6162
Ji-Young YoonMedical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, Republic of Korea.ORCID 0000-0002-8588-8664
Hyoung-Kwon LeeResearch Laboratory, Green Optics CO, Cheongju, Republic of Korea.ORCID 0000-0001-9611-1087
Nak-Gu ChoiResearch Lab, Hulust CO, Wonju, Republic of Korea.ORCID 0000-0001-5832-6757
Il-Ho ParkDepartment of Otorhinolaryngology, Korea University Medical College, Seoul, Republic of Korea.ORCID 0000-0002-7011-6071
Hae-Young ChoiMedical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, Republic of Korea.ORCID 0000-0001-7962-2029
Daegu-Gyeongbuk Medical Innovation Foundation · KRKorea University Medical Center · KRKyungpook National University · KRPohang University of Science and Technology · KRSangji University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe surgical microscope is used primarily for microsurgeries, which are more complicated than other surgical procedures and require delicate tasks for a long time. Therefore, during these surgical procedures, surgeons experience back and neck pain. To solve this problem, new technology, such as wearable displays, is required to help surgeons maintain comfortable postures and enjoy advanced functionality during microsurgery.

objectiveThe objective of this study was to develop a surgical microscope system that would work with wearable devices. It would include a head-mounted display (HMD) that can offer 3D surgical images and allow a flexible and comfortable posture instead of fixed eyepieces of surgical microscope and can also provide peripheral visual field with its optical see-through function.

methodsWe designed and fabricated a surgical microscope system that incorporates a see-through type 3D HMD, and we developed an image processing software to provide better image quality. The usability of the proposed system was confirmed with preclinical examination. Seven ENT (ear, nose, and throat) surgical specialists and 8 residents performed a mock surgery-axillary lymph node dissection on a rat. They alternated between looking through the eyepieces of the surgical microscope and viewing a 3D HMD screen connected to the surgical microscope. We examined the success of the surgery and asked the specialists and residents to grade eye fatigue on a scale of 0 (none) to 6 (severe) and posture discomfort on a scale of 1 (none) to 5 (severe). Furthermore, a statistical comparison was performed using 2-tailed paired t test, and P=.00083 was considered significant.

resultsAlthough 3D HMD case showed a slightly better result regarding visual discomfort (P=.097), the average eye fatigue was not significantly different between eyepiece and 3D HMD cases (P=.79). However, the average posture discomfort, especially in neck and shoulder, was lower with 3D HMD display use than with eyepiece use (P=.00083).

conclusionsWe developed a see-through type 3D HMD-based surgical microscope system and showed through preclinical testing that the system could help reduce posture discomfort. The proposed system, with its advanced functions, could be a promising new technique for microsurgery.

Indexed as

AdultAnimalsAsthenopiaDisease Models, AnimalFeasibility StudiesHumansImaging, Three-DimensionalMaleMicroscopyMicrosurgeryOral and Maxillofacial SurgeonsRatsSmart GlassesSurgical InstrumentsWearable Electronic Devices3D imaginghead-mounted displaymicrosurgerysurgical microscope

Identifiers

PMID30843867
PMCPMC6427099
OpenAlexW2900820800

What OpenQuestion holds