Evidence map›Paper›PMID 30842456›Full record

ArticleScientific reports2019

Voltage readout from a piezoelectric intracochlear acoustic transducer implanted in a living guinea pig.

Chuming Zhao, Katherine E Knisely, Deborah J Colesa, Bryan E Pfingst, Yehoash Raphael, Karl Grosh

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 32 citations in OpenAlex.

  1. Review
  2. Review
  3. MEMS piezoelectric resonant microphone array for lung sound classification.Journal of micromechanics and microengineering : structures, devices, and systems · 2023
    Article
  4. Review
  5. Article
  6. Article
  7. Relationships between Intrascalar Tissue, Neuron Survival, and Cochlear Implant Function.Journal of the Association for Research in Otolaryngology : JARO · 2020
    Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Chuming ZhaoDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA.ORCID 0000-0001-8104-5902
Katherine E KniselyDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA.
Deborah J ColesaKresge Hearing Research Institute, Department of Otolaryngology - Head and Neck Surgery, University of Michigan, Ann Arbor, MI, 48109, USA.
Bryan E PfingstKresge Hearing Research Institute, Department of Otolaryngology - Head and Neck Surgery, University of Michigan, Ann Arbor, MI, 48109, USA.
Yehoash RaphaelKresge Hearing Research Institute, Department of Otolaryngology - Head and Neck Surgery, University of Michigan, Ann Arbor, MI, 48109, USA.
Karl GroshDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA. grosh@umich.edu.
University of Michigan · US

Funding

Scientific Synergy CoreP30DC005188 · NIDCD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI SCHACHT, JOCHEN · 2002 to 2016
$10.3M
NIDCD NIH HHS P30 DC005188
6 · The paper itself

Abstract

The ability to measure the voltage readout from a sensor implanted inside the living cochlea enables continuous monitoring of intracochlear acoustic pressure locally, which could improve cochlear implants. We developed a piezoelectric intracochlear acoustic transducer (PIAT) designed to sense the acoustic pressure while fully implanted inside a living guinea pig cochlea. The PIAT, fabricated using micro-electro-mechanical systems (MEMS) techniques, consisted of an array of four piezoelectric cantilevers with varying lengths to enhance sensitivity across a wide frequency bandwidth. Prior to implantation, benchtop tests were conducted to characterize the device performance in air and in water. When implanted in the cochlea of an anesthetized guinea pig, the in vivo voltage response from the PIAT was measured in response to 80-95 dB sound pressure level 1-14 kHz sinusoidal acoustic excitation at the entrance of the guinea pig's ear canal. All sensed signals were above the noise floor and unaffected by crosstalk from the cochlear microphonic or external electrical interference. These results demonstrate that external acoustic stimulus can be sensed via the piezoelectric voltage response of the implanted MEMS transducer inside the living cochlea, providing key steps towards developing intracochlear acoustic sensors to replace external or subcutaneous microphones for auditory prosthetics.

Indexed as

AcousticsAcoustic StimulationAnimalsCochleaCochlear ImplantationCochlear ImplantsEar CanalEvoked Potentials, Auditory, Brain StemGuinea PigsPiezosurgerySoundTransducers

Identifiers

PMID30842456
PMCPMC6403321
OpenAlexW2919195726

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.