Evidence map›Paper›PMID 30841646›Full record

ArticleSensors (Basel, Switzerland)2019

Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications.

Yugang Chen, Yong-Hwa Park

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 10 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Yugang ChenDepartment of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Korea.
Yong-Hwa ParkDepartment of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Korea. yhpark@kaist.ac.kr.
Korea Advanced Institute of Science and Technology · KR

Funding

Korea Agency for Infrastructure Technology Advancement Research Project for Railway TechnologyKorea Institute of Energy Technology Evaluation and Planning 20184030202000
6 · The paper itself

Abstract

In this paper, an indirect method of measuring an analyte concentration in a test solution using the resonant frequency change of a Helmholtz resonator is proposed, using a novel architecture of Helmholtz resonator filled with two kinds of fluids (fixed fluid and test solution). Since the analyte concentration yields changes of density and sound speed of the test solution, the resonant frequency of the proposed Helmholtz resonator is affected by the analyte concentration of the test solution. From this effect, the analyte concentration of the test solution can be measured by the spectrum of acoustic resonance of the Helmholtz resonator. The experiment was done using a 3D-printed Helmholtz resonator system with an acoustic power source and detectors, which is consistent with analytical results and showed that the analyte concentration can be measured with higher sensitivity compared to conventional cantilever-type sensors. As an example application, the possibility of measuring glucose concentration of human blood was demonstrated, showing higher sensitivity and relatively low frequency range compared to previous resonance based methods.

Indexed as

Biosensing TechniquesGlucoseHumansGlucoseanalyte concentrationglucose sensorHelmholtz resonatorindirect measurementresonant frequency

Identifiers

PMID30841646
PMCPMC6427302
OpenAlexW2919889120

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked