Evidence map›Paper›PMID 30838793›Full record

ArticleInternational journal for numerical methods in biomedical engineering2019

Suitability of lattice Boltzmann inlet and outlet boundary conditions for simulating flow in image-derived vasculature.

Bradley Feiger, Madhurima Vardhan, John Gounley, Matthew Mortensen, Priya Nair, Rafeed Chaudhury, David Frakes, Amanda Randles

Open access · greenAbstract read
In one paragraph

Article in International journal for numerical methods in biomedical engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
3.3field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Propagation pattern for moment representation of the lattice Boltzmann method.IEEE transactions on parallel and distributed systems : a publication of the IEEE Computer Society · 2022
    Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Bradley FeigerDepartment of Biomedical Engineering, Duke University, Durham, NC, USA.
Madhurima VardhanDepartment of Biomedical Engineering, Duke University, Durham, NC, USA.
John GounleyDepartment of Biomedical Engineering, Duke University, Durham, NC, USA.
Matthew MortensenDepartment of Biomedical Engineering, Arizona State University, Tempe, AZ, USA.
Priya NairDepartment of Biomedical Engineering, Arizona State University, Tempe, AZ, USA.
Rafeed ChaudhuryDepartment of Biomedical Engineering, Arizona State University, Tempe, AZ, USA.
David FrakesDepartment of Biomedical Engineering, Arizona State University, Tempe, AZ, USA.
Amanda RandlesDepartment of Biomedical Engineering, Duke University, Durham, NC, USA.ORCID 0000-0001-6318-3885
Arizona State University · USDuke University · US

Funding

Toward coupled multiphysics models of hemodynamics on leadership systemsDP5OD019876 · OD · UNIVERSITY OF CALIF-LAWRNC LVRMR NAT LAB · PI RANDLES, AMANDA E · 2014 to 2018
$2.0M
NIH HHS DP5 OD019876NIH HHS DP5OD019876
6 · The paper itself

Abstract

The lattice Boltzmann method (LBM) is a popular alternative to solving the Navier-Stokes equations for modeling blood flow. When simulating flow using the LBM, several choices for inlet and outlet boundary conditions exist. While boundary conditions in the LBM have been evaluated in idealized geometries, there have been no extensive comparisons in image-derived vasculature, where the geometries are highly complex. In this study, the Zou-He (ZH) and finite difference (FD) boundary conditions were evaluated in image-derived vascular geometries by comparing their stability, accuracy, and run times. The boundary conditions were compared in four arteries: a coarctation of the aorta, dissected aorta, femoral artery, and left coronary artery. The FD boundary condition was more stable than ZH in all four geometries. In general, simulations using the ZH and FD method showed similar convergence rates within each geometry. However, the ZH method proved to be slightly more accurate compared with experimental flow using three-dimensional printed vasculature. The total run times necessary for simulations using the ZH boundary condition were significantly higher as the ZH method required a larger relaxation time, grid resolution, and number of time steps for a simulation representing the same physiological time. Finally, a new inlet velocity profile algorithm is presented for complex inlet geometries. Overall, results indicated that the FD method should generally be used for large-scale blood flow simulations in image-derived vasculature geometries. This study can serve as a guide to researchers interested in using the LBM to simulate blood flow.

Indexed as

AlgorithmsComputer SimulationImage Processing, Computer-AssistedAortaBlood Flow VelocityCoronary VesselsHydrodynamicsReproducibility of ResultsRheologyTime Factorsboundary conditionsfinite differencehemodynamicsimage-derived vasculaturelattice Boltzmann methodZou-He

Identifiers

PMID30838793
PMCPMC7605305
OpenAlexW2921354717

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.