Siamak P Nejad-Davarani, Joshua P Kim, Dongsu Du, Carri Glide-Hurst

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
3.4field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Development of a vendor neutral MRI distortion quality assurance workflow.Journal of applied clinical medical physics · 2022
    Article
  6. Article
  7. Article
  8. Effects of BMedical physics · 2021
    Article
  9. Article
  10. MRI-Guided Radiation Therapy.Advances in oncology · 2021
    Article
  11. Review
  12. Article
  13. BMedical physics · 2020
    Article
  14. Article
  15. MRI quality control for low-field MR-IGRT systems: Lessons learned.Journal of applied clinical medical physics · 2019
    Article
  16. Technical design and concept of a 0.35 T MR-Linac.Clinical and translational radiation oncology · 2019
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Siamak P Nejad-DavaraniDepartment of Radiation Oncology, Henry Ford Cancer Institute, 2799 West Grand Blvd., Detroit, MI, 48202, USA.
Joshua P KimDepartment of Radiation Oncology, Henry Ford Cancer Institute, 2799 West Grand Blvd., Detroit, MI, 48202, USA.
Dongsu DuDepartment of Radiation Oncology, Henry Ford Cancer Institute, 2799 West Grand Blvd., Detroit, MI, 48202, USA.
Carri Glide-HurstDepartment of Radiation Oncology, Henry Ford Cancer Institute, 2799 West Grand Blvd., Detroit, MI, 48202, USA.
Henry Ford Hospital · US

Funding

Development of Anatomical Patient Models to Facilitate MR-only Treatment PlanningR01CA204189 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI GLIDE-HURST, CARRI KAYE · 2016 to 2020
$1.5M
NCI NIH HHS R01 CA204189NIH HHS R01CA204189
6 · The paper itself

Abstract

purposeMR-guided radiation therapy (RT) offers unparalleled soft tissue contrast for localization and target tracking. However, MRI distortions may be detrimental to high precision RT. This work characterizes the gradient nonlinearity (GNL) and total distortions over the first year of clinical operation of a 0.35T MR-linac.

methodsFor GNL characterization, an in-house large field of view (FOV) phantom (60 × 42.5 × 55 cm

resultsThe scanner's spatial integrity within the first ~10 months was stable (maximum total distortion variation = 10/6/8%, maximum distortion = 1.41/0.99/1.56 mm in Axial/Coronal/Sagittal planes, respectively). GNL distortions measured during this time period <10 cm from isocenter were (-0.74, 0.45), (-0.67, 0.53), and (-0.86, 0.70) mm in AP/LR/SI directions. In the 10-20 cm range, <1.5% of the distortions exceeded 2 mm in the AP and LR axes while <4% of the distortions exceeded 2 mm for SI. After major repairs and magnet re-shim, detectable changes were observed in total and GNL distortions (20% reduction in AP and 36% increase in SI direction in the 20-25 cm range). Across all timepoints and axes, 38-53% of landmarks in the 20-25 cm range were displaced by >1 mm.

conclusionsGNL distortions were negligible within a 10 cm radius from isocenter. However, in the periphery, non-negligible distortions of up to ~7 mm were observed, which may necessitate GNL corrections for MR-IGRT for treatment sites distant from magnet isocenter.

Indexed as

Particle AcceleratorsImage Processing, Computer-AssistedMagnetic Resonance ImagingNonlinear DynamicsPhantoms, ImagingRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssisteddistortionMRIMR-IGRT

Identifiers

PMID30838680
PMCPMC6510606
OpenAlexW2921607199

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.