Evidence map›Paper›PMID 30834319›Full record

ArticleACS central science2019

Nanoscale Ion Emitters in Native Mass Spectrometry for Measuring Ligand-Protein Binding Affinities.

Giang T H Nguyen, Thinh N Tran, Matthew N Podgorski, Stephen G Bell, Claudiu T Supuran, William A Donald

Abstract read
In one paragraph

Article in ACS central science, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 45 papers.

0numbers the graph read from it
0cells of the map it votes in
45citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

45 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. ZnJournal of the American Chemical Society · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Giang T H NguyenSchool of Chemistry, University of New South Wales, Dalton Building, Sydney, New South Wales 2052, Australia.
Thinh N TranSchool of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, New South Wales 2052, Australia.
Matthew N PodgorskiDepartment of Chemistry, University of Adelaide, Adelaide, South Australia 5005, Australia.
Stephen G BellDepartment of Chemistry, University of Adelaide, Adelaide, South Australia 5005, Australia.
Claudiu T SupuranDepartment of Neuroscience, Psychology, Drug Research and Child's Health, Section of Pharmaceutical and Nutraceutical Sciences, University of Florence, Via Ugo Schiff 6, 50019 Sesto Fiorentino, Italy.
William A DonaldSchool of Chemistry, University of New South Wales, Dalton Building, Sydney, New South Wales 2052, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrospray ionization (ESI) mass spectrometry (MS) is a crucial method for rapidly determining the interactions between small molecules and proteins with ultrahigh sensitivity. However, nonvolatile molecules and salts that are often necessary to stabilize the native structures of protein-ligand complexes can readily adduct to protein ions, broaden spectral peaks, and lower signal-to-noise ratios in native MS. ESI emitters with narrow tip diameters (∼250 nm) were used to significantly reduce the extent of adduction of salt and nonvolatile molecules to protein complexes to more accurately measure ligand-protein binding constants than by use of conventional larger-bore emitters under these conditions. As a result of decreased salt adduction, peaks corresponding to protein-ligand complexes that differ in relative molecular weight by as low as 0.06% can be readily resolved. For low-molecular-weight anion ligands formed from sodium salts, anion-bound and unbound protein ions that differ in relative mass by 0.2% were completely baseline resolved using nanoscale emitters, which was not possible under these conditions using conventional emitters. Owing to the improved spectral resolution obtained using narrow-bore emitters and an analytically derived equation,

Identifiers

PMID30834319
PMCPMC6396573

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.