Evidence map›Paper›PMID 30832254›Full record

ArticleBiosensors2019

Solid-State rGO-PEDOT:PSS Transducing Material for Cost-Effective Enzymatic Sensing.

Firdaus Abd-Wahab, Habibah Farhana Abdul Guthoos, Wan Wardatul Amani Wan Salim

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
3.6field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 55 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Firdaus Abd-WahabDepartment of Biotechnology Engineering, Faculty of Engineering, International Islamic University Malaysia, Gombak 50728, Kuala Lumpur, Malaysia. firdaus@iium.edu.my.
Habibah Farhana Abdul GuthoosDepartment of Biotechnology Engineering, Faculty of Engineering, International Islamic University Malaysia, Gombak 50728, Kuala Lumpur, Malaysia. habibahfarhana@gmail.com.
Wan Wardatul Amani Wan SalimDepartment of Biotechnology Engineering, Faculty of Engineering, International Islamic University Malaysia, Gombak 50728, Kuala Lumpur, Malaysia. asalim@iium.edu.my.ORCID 0000-0003-1607-105X
International Islamic University Malaysia · MY

Funding

FDNANO Ventures Ltd. SP18-110-0372International Islamic University Malaysia RIGS17-011-0586International Islamic University Malaysia RPDF18-002-0002
6 · The paper itself

Abstract

Performance of a sensing device is dependent on its construction material, especially for components that are directly involved in transporting and translating signals across the device. Understanding the morphology and characteristics of the material components is therefore crucial in the development of any sensing device. This work examines the morphological and electrochemical characteristics of reduced graphene oxide interspersed with poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (rGO-PEDOT:PSS) used as a transducer material deposited on a commercially available screen-printed carbon electrode (SPCE). Electron microscopy shows that PEDOT:PSS is interspersed between rGO layers. Raman and XRD analyses suggest that the graphene crystallinity in GO-PEDOT:PSS and rGO-PEDOT:PSS remains intact. Instead, PEDOT:PSS undergoes a change in structure to allow PEDOT to blend into the graphene structure and partake in the π-π interaction with the surface of the rGO layers. Incorporation of PEDOT:PSS also appears to improve the electrochemical behavior of the composite, leading to a higher peak current of 1.184 mA, as measured by cyclic voltammetry, compared to 0.522 mA when rGO is used alone. The rGO-PEDOT:PSS transducing material blended with glucose oxidase was tested for glucose detection. The sensitivity of glucose detection was shown to be 57.3 µA/(mM·cm²) with a detection limit of 86.8 µM.

Indexed as

Biosensing TechniquesElectrochemical TechniquesGlucoseGlucose OxidaseGraphiteHumansMicroscopy, ElectronNanocompositesPolystyrenesThiophenesGlucoseGlucose Oxidasegraphene oxideGraphitepoly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate)PolystyrenesThiophenescyclic voltammetryelectrochemical reductionglucose oxidasePEDOT:PSSreduced graphene oxidescreen-printed carbon electrodesurface characterization

Identifiers

PMID30832254
PMCPMC6468658
OpenAlexW2918696022

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked