Evidence map›Paper›PMID 30825245›Full record

ArticleMagnetic resonance in medicine2019

Reducing distortions in echo-planar breast imaging at ultrahigh field with high-resolution off-resonance maps.

Michael J van Rijssel, Frank Zijlstra, Peter R Seevinck, Peter R Luijten, Kenneth G A Gilhuijs, Dennis W J Klomp, Josien P W Pluim

Open access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Michael J van RijsselCenter for Image Sciences, UMC Utrecht, Utrecht, The Netherlands.ORCID 0000-0002-2365-4408
Frank ZijlstraCenter for Image Sciences, UMC Utrecht, Utrecht, The Netherlands.ORCID 0000-0002-9184-7666
Peter R SeevinckCenter for Image Sciences, UMC Utrecht, Utrecht, The Netherlands.
Peter R LuijtenCenter for Image Sciences, UMC Utrecht, Utrecht, The Netherlands.
Kenneth G A GilhuijsCenter for Image Sciences, UMC Utrecht, Utrecht, The Netherlands.
Dennis W J KlompCenter for Image Sciences, UMC Utrecht, Utrecht, The Netherlands.
Josien P W PluimCenter for Image Sciences, UMC Utrecht, Utrecht, The Netherlands.
Utrecht University · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDWI is a promising modality in breast MRI, but its clinical acceptance is slow. Analysis of DWI is hampered by geometric distortion artifacts, which are caused by off-resonant spins in combination with the low phase-encoding bandwidth of the EPI sequence used. Existing correction methods assume smooth off-resonance fields, which we show to be invalid in the human breast, where high discontinuities arise at tissue interfaces.

methodsWe developed a distortion correction method that incorporates high-resolution off-resonance maps to better solve for severe distortions at tissue interfaces. The method was evaluated quantitatively both ex vivo in a porcine tissue phantom and in vivo in 5 healthy volunteers. The added value of high-resolution off-resonance maps was tested using a Wilcoxon signed rank test comparing the quantitative results obtained with a low-resolution off-resonance map with those obtained with a high-resolution map.

resultsDistortion correction using low-resolution off-resonance maps corrected most of the distortions, as expected. Still, all quantitative comparison metrics showed increased conformity between the corrected EPI images and a high-bandwidth reference scan for both the ex vivo and in vivo experiments. All metrics showed a significant improvement when a high-resolution off-resonance map was used (P < 0.05), in particular at tissue boundaries.

conclusionThe use of off-resonance maps of a resolution higher than EPI scans significantly improves upon existing distortion correction techniques, specifically by superior correction at glandular tissue boundaries.

Indexed as

AdultAlgorithmsAnimalsBreastEcho-Planar ImagingFemaleHumansImage Processing, Computer-AssistedMiddle AgedModels, BiologicalPhantoms, ImagingSwine7TB0 mappingbreastdiffusion-weighted imagingdistortion correctionecho-planar imagingoff-resonance

Identifiers

PMID30825245
PMCPMC6593992
OpenAlexW2920760723

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.