Evidence map›Paper›PMID 30823435›Full record

ReviewSensors (Basel, Switzerland)2019

Current Advancements in Transdermal Biosensing and Targeted Drug Delivery.

Prem C Pandey, Shubhangi Shukla, Shelby A Skoog, Ryan D Boehm, Roger J Narayan

Abstract readReview
In one paragraph

Review in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Review
  8. Review
  9. Evaluation test and analysis of a microneedle and iontophoresis based medical device "CELLADEEP Patch" in skin improvement on ex vivo human-derived skin tissue models.Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI) · 2024
    Article
  10. Review
  11. Article
  12. Review
  13. Review
  14. Review
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Prem C PandeyDepartment of Chemistry, Indian Institute of Technology (BHU), Varanasi 221005, India. pcpandey.apc@iitbhu.ac.in.ORCID 0000-0002-6053-902X
Shubhangi ShuklaDepartment of Chemistry, Indian Institute of Technology (BHU), Varanasi 221005, India. sbshukla1990@gmail.com.
Shelby A SkoogJoint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Raleigh, NC 27695, USA. saskoog@gmail.com.
Ryan D BoehmJoint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Raleigh, NC 27695, USA. ryandboehm@gmail.com.
Roger J NarayanJoint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Raleigh, NC 27695, USA. rjnaraya@ncsu.edu.

Funding

Science and Engineering Research Board DST Grant Number VJR-2017-000034.
6 · The paper itself

Abstract

In this manuscript, recent advancements in the area of minimally-invasive transdermal biosensing and drug delivery are reviewed. The administration of therapeutic entities through the skin is complicated by the stratum corneum layer, which serves as a barrier to entry and retards bioavailability. A variety of strategies have been adopted for the enhancement of transdermal permeation for drug delivery and biosensing of various substances. Physical techniques such as iontophoresis, reverse iontophoresis, electroporation, and microneedles offer (a) electrical amplification for transdermal sensing of biomolecules and (b) transport of amphiphilic drug molecules to the targeted site in a minimally invasive manner. Iontophoretic delivery involves the application of low currents to the skin as well as the migration of polarized and neutral molecules across it. Transdermal biosensing via microneedles has emerged as a novel approach to replace hypodermic needles. In addition, microneedles have facilitated minimally invasive detection of analytes in body fluids. This review considers recent innovations in the structure and performance of transdermal systems.

Indexed as

Administration, CutaneousAnimalsBiosensing TechniquesDrug Delivery SystemsElectroporationHumansIontophoresisNeedlesPharmaceutical PreparationsPharmaceutical Preparationsdrug deliveryelectroporationfluorescent biosensorsIontophoresisluminescent sensorsmicrofabricationmicrofluidicsmicroneedletransdermal biosensing

Identifiers

PMID30823435
PMCPMC6427209

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.