Evidence map›Paper›PMID 30813494›Full record

ArticleSensors (Basel, Switzerland)2019

Ultra-Low-Power Digital Filtering for Insulated EMG Sensing.

Theresa Roland, Sebastian Amsuess, Michael F Russold, Werner Baumgartner

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Theresa RolandInstitute of Biomedical Mechatronics, Johannes Kepler University Linz, 4040 Linz, Austria. theresa.roland@jku.at.
Sebastian AmsuessResearch and Development, Otto Bock Healthcare Products GmbH, 1110 Vienna, Austria. sebastian.amsuess@ottobock.com.
Michael F RussoldResearch and Development, Otto Bock Healthcare Products GmbH, 1110 Vienna, Austria. michael.russold@ottobock.com.
Werner BaumgartnerInstitute of Biomedical Mechatronics, Johannes Kepler University Linz, 4040 Linz, Austria. werner.baumgartner@jku.at.

Funding

Linz Center of Mechatronics -Linz Institute of Technology -
6 · The paper itself

Abstract

Myoelectric prostheses help amputees to regain independence and a higher quality of life. These prostheses are controlled by state-of-the-art electromyography sensors, which use a conductive connection to the skin and are therefore sensitive to sweat. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Here, we present ultra-low-power digital signal processing algorithms for an insulated EMG sensor which couples the EMG signal capacitively. These sensors require neither conductive connection to the skin nor electrolytic paste or skin preparation. Capacitive sensors allow straightforward application. However, they make a sophisticated signal amplification and noise suppression necessary. A low-cost sensor has been developed for real-time myoelectric prostheses control. The major hurdles in measuring the EMG are movement artifacts and external noise. We designed various digital filters to attenuate this noise. Optimal system setup and filter parameters for the trade-off between attenuation of this noise and sufficient EMG signal power for high signal quality were investigated. Additionally, an algorithm for movement artifact suppression, enabling robust application in real-world environments, is presented. The algorithms, which require minimal calculation resources and memory, are implemented on an ultra-low-power microcontroller.

Indexed as

AlgorithmsElectromyographyHumansQuality of LifeSignal Processing, Computer-Assistedbiosignal processingEMG signal processinginsulated/capacitive EMGlow power filteringmyoelectric upper-limb prosthesis

Identifiers

PMID30813494
PMCPMC6412999

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.