ArticlePloS one2019
Manual polishing of 3D printed metals produced by laser powder bed fusion reduces biofilm formation.
Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 29 citations in OpenAlex.
- Recent Research Progress in the Abrasive Machining and Finishing of Additively Manufactured Metal Parts.Materials (Basel, Switzerland) · 2025Review
- Silver multilayer coating on orthopedic implant material of different alloys and surfaces significantly reduces bacterial colonization.Frontiers in cellular and infection microbiology · 2025Article
- The Interaction between Oral Bacteria and 3D Titanium Porous Surfaces Produced by Selective Laser Melting-A Narrative Review.Biomimetics (Basel, Switzerland) · 2024Review
- Surface Enhancement of Additively Manufactured Bone Plate Through Hybrid-Electrochemical Magnetorheological Finishing Process.3D printing and additive manufacturing · 2024Article
- Induction Heating Triggers Antibiotic Release and Synergistic Bacterial Killing on Polymer-Coated Titanium Surfaces.Advanced healthcare materials · 2023Article
- Human Gingival Fibroblast Attachment to Smooth Titanium Disks with Different Surface Roughnesses.Biomimetics (Basel, Switzerland) · 2022Article
- Effect of surface topography on in vitro osteoblast function and mechanical performance of 3D printed titanium.Journal of biomedical materials research. Part A · 2021Article
- The Removal of Meat Exudate andInternational journal of environmental research and public health · 2021Article
- Susceptibility to biofilm formation on 3D-printed titanium fixation plates used in the mandible: a preliminary study.Journal of oral microbiology · 2020Article
- The Impact of EBM-Manufactured Ti6Al4V ELI Alloy Surface Modifications on Cytotoxicity toward Eukaryotic Cells and Microbial Biofilm Formation.Materials (Basel, Switzerland) · 2020Article
- Biomaterial-based possibilities for managing peri-implantitis.Journal of periodontal research · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Certain 3D printed metals and surface finishes may be better suited for canine patient specific orthopedic implants on the basis of minimizing potential bacterial biofilm growth. Thirty disks each of titanium alloy, stainless steel, and cobalt chromium alloy were 3D printed via laser powder bed fusion. Fifteen disks of each metal were subsequently polished. After incubation with a robust biofilm-forming methicillin-resistant Staphylococcus pseudintermedius isolate, disks were rinsed and sonicated to collect biofilm bacteria. Serial dilutions were plated on blood agar, and colony forming units were counted log (ln) transformed for analysis of variance. Interference microscopy quantified surface roughness for comparison to biofilm growth. Scanning electron microscopy on both pre- and post-sonicated disks confirmed biofilm presence and subsequent removal, and visualized surface features on cleaned disks. Significantly more bacteria grew on rough versus polished metal preparations (p < 0.0001). Titanium alloy had more bacterial biofilm growth compared to cobalt chromium alloy (p = 0.0001) and stainless steel (p < 0.0001). There were no significant growth differences between cobalt chromium alloy and stainless steel (p = 0.4737). Relationships between biofilm growth and surface roughness varied: positive with the rough preparations and negative with the smooth. Polished preparations had increased variance in surface roughness compared to rough preparations, and within disk variance predominated over between disk variance for all preparations with the exception of rough cobalt chromium alloy and rough stainless steel. Using scanning electron microscopy, bacterial biofilms tended to form in crevices. Overall, manual polishing of 3D printed surfaces significantly reduced biofilm growth, with preparation-specific relationships between surface roughness and biofilm growth. These results suggest that metallic implants produced by laser powder bed fusion should be polished. Further research will elucidate the optimal surface roughness per preparation to reduce potential biofilm formation and implant associated infection.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.