Evidence map›Paper›PMID 30811509›Full record

ArticlePloS one2019

Manual polishing of 3D printed metals produced by laser powder bed fusion reduces biofilm formation.

Marissa McGaffey, Alex Zur Linden, Nathanael Bachynski, Michelle Oblak, Fiona James, J Scott Weese

Open access · goldAbstract readComparative Study
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.9field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 29 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. The Removal of Meat Exudate andInternational journal of environmental research and public health · 2021
    Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Marissa McGaffeyDepartment of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada.ORCID 0000-0002-5605-8223
Alex Zur LindenDepartment of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada.ORCID 0000-0002-5663-0197
Nathanael BachynskiDepartment of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada.
Michelle OblakDepartment of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada.
Fiona JamesDepartment of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada.ORCID 0000-0003-4331-4993
J Scott WeeseDepartment of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada.
University of Guelph · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Certain 3D printed metals and surface finishes may be better suited for canine patient specific orthopedic implants on the basis of minimizing potential bacterial biofilm growth. Thirty disks each of titanium alloy, stainless steel, and cobalt chromium alloy were 3D printed via laser powder bed fusion. Fifteen disks of each metal were subsequently polished. After incubation with a robust biofilm-forming methicillin-resistant Staphylococcus pseudintermedius isolate, disks were rinsed and sonicated to collect biofilm bacteria. Serial dilutions were plated on blood agar, and colony forming units were counted log (ln) transformed for analysis of variance. Interference microscopy quantified surface roughness for comparison to biofilm growth. Scanning electron microscopy on both pre- and post-sonicated disks confirmed biofilm presence and subsequent removal, and visualized surface features on cleaned disks. Significantly more bacteria grew on rough versus polished metal preparations (p < 0.0001). Titanium alloy had more bacterial biofilm growth compared to cobalt chromium alloy (p = 0.0001) and stainless steel (p < 0.0001). There were no significant growth differences between cobalt chromium alloy and stainless steel (p = 0.4737). Relationships between biofilm growth and surface roughness varied: positive with the rough preparations and negative with the smooth. Polished preparations had increased variance in surface roughness compared to rough preparations, and within disk variance predominated over between disk variance for all preparations with the exception of rough cobalt chromium alloy and rough stainless steel. Using scanning electron microscopy, bacterial biofilms tended to form in crevices. Overall, manual polishing of 3D printed surfaces significantly reduced biofilm growth, with preparation-specific relationships between surface roughness and biofilm growth. These results suggest that metallic implants produced by laser powder bed fusion should be polished. Further research will elucidate the optimal surface roughness per preparation to reduce potential biofilm formation and implant associated infection.

Indexed as

AlloysAnimalsBiofilmsBone-Anchored ProsthesisChromium AlloysDogsLasersMethicillin ResistanceMicroscopy, Electron, ScanningMicroscopy, InterferencePowdersPrinting, Three-DimensionalProstheses and ImplantsSonicationStainless SteelStaphylococcusAlloysChromium AlloysPowdersStainless SteelTitanium

Identifiers

PMID30811509
PMCPMC6392326
OpenAlexW2916020868

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.