ArticleMikrochimica acta2019
ZnS quantum dots surface-loaded with zinc(II) ions as a viable fluorescent probe for glutathione.
Article in Mikrochimica acta, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Miniaturized Fluorimetric Method for Quantification of Zinc in Dry Dog Food.Journal of analytical methods in chemistry · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The fluorescence of ZnS quantum dots in colloidal water solution changes very slightly on addition of glutathione (GSH) but is strongly enhanced in the presence of Zn(II) even in concentrations as low as 10 μM. The resulting Zn(II)-enhanced fluorescence is found to be quenched by GSH. In contrast to GSH, cysteine does not cause an effect. Response surface methodology was applied to optimize the experimental parameters. The best data can be obtained at 305/427 nm as excitation/emission wavelengths. These findings were used to design an indirect method for the fluorometric determination of GSH that has a 0.9 μM detection limit and a response that is linear in the 2.0-104.0 μM GSH concentration range. The relative standard deviation at a level of 65 μM of GSH (for n = 5) is 1.9%. Graphical abstract Schematic presentation of the detection strategy for glutathione and the influence of the mediator (Zn
Indexed as
Identifiers
30806793What OpenQuestion holds
Registered trials