Evidence map›Paper›PMID 30800526›Full record

ArticleBiomedical optics express2019

Diffuse reflectance spectroscopy-enhanced drill for bone boundary detection.

Matthieu Duperron, Konstantin Grygoryev, Gerard Nunan, Cormac Eason, Jacqueline Gunther, Ray Burke, Kevin Manley, Peter O'brien

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Matthieu DuperronTyndall National Institute, Lee Maltings Complex, Dyke parade, Cork, Ireland, T12R5CP.
Konstantin GrygoryevTyndall National Institute, Lee Maltings Complex, Dyke parade, Cork, Ireland, T12R5CP.
Gerard NunanStryker, Instruments Innovation Centre, IDA Business and Technology Park, Carrigtwohill, Cork, Ireland.
Cormac EasonTyndall National Institute, Lee Maltings Complex, Dyke parade, Cork, Ireland, T12R5CP.
Jacqueline GuntherTyndall National Institute, Lee Maltings Complex, Dyke parade, Cork, Ireland, T12R5CP.
Ray BurkeTyndall National Institute, Lee Maltings Complex, Dyke parade, Cork, Ireland, T12R5CP.
Kevin ManleyStryker, Instruments Innovation Centre, IDA Business and Technology Park, Carrigtwohill, Cork, Ireland.
Peter O'brienTyndall National Institute, Lee Maltings Complex, Dyke parade, Cork, Ireland, T12R5CP.
Stryker (Ireland) · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intramedullary nailing is a routine orthopedic procedure used for treating fractures of femoral or tibial shafts. A critical part of this procedure involves the drilling of pilot holes in both ends of the bone for the placement of the screws that will secure the IM rod to sections of the fractured bone. This step introduces a risk of soft tissue damage because the drill bit, if not stopped in time, can transverse the bone-tissue boundary into the overlying muscle, causing unnecessary injury and prolonging healing time due to periosteum damage. In this respect, detecting the bone-tissue boundary before break-through can reduce the risks and complications associated with intramedullary nailing. Hence, in the present study, a two-wavelength diffuse reflectance spectroscopy technique was integrated into a surgical drill to optically detect bone-tissue boundary and automatically trigger the drill to stop. Furthermore, Monte-Carlo simulations were used to estimate the maximum distance from within the bone at which the bone-tissue boundary could be detected using DRS. The simulation results estimated that the detection distance, termed the "look-ahead-distance" was ∼1.5 mm for 1.3 mm source-detector fiber separation. Experimental measurements with 1.3 mm source-detector fiber separation showed that the look-ahead-distance was in the order of 250

Identifiers

PMID30800526
PMCPMC6377869
OpenAlexW2914173485

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.