Evidence map›Paper›PMID 30800507›Full record

ArticleBiomedical optics express2019

Light-sheet microscopy with length-adaptive Bessel beams.

Tobias Meinert, Alexander Rohrbach

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
5.0field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 33 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Tobias MeinertLaboratory for Bio-and Nano Photonics, Department of Microsystems Engineering - IMTEK, University of Freiburg, Freiburg 79110, Germany.
Alexander RohrbachLaboratory for Bio-and Nano Photonics, Department of Microsystems Engineering - IMTEK, University of Freiburg, Freiburg 79110, Germany.
University of Freiburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In light-sheet microscopy, a confined layer in the focal plane of the detection objective is illuminated from the side. The illumination light-sheet usually has a constant beam length independent of the shape of the biological object. Since the thickness and the length of the illumination light-sheet are coupled, a tradeoff between resolution, contrast and field of view has to be accepted. Here we show that scanned Bessel beams enable object adapted tailoring of the light-sheet defined by its beam length and position. The individual beam parameters are obtained from automatic object shape estimation by low-power laser light scattered at the object. Using Arabidopsis root tips, cell clusters and zebrafish tails, we demonstrate that Bessel beam light-sheet tailoring leads to a 50% increase in image contrast and a 50% reduction in photobleaching. Light-sheet tailoring requires only binary amplitude modulation, therefore allowing a real time illumination adaptation with little technical effort in the future.

Identifiers

PMID30800507
PMCPMC6377868
OpenAlexW2910546794

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.