Assistive technology using integrated flexible sensor and virtual alarm unit for blood leakage detection during dialysis therapy.

Chia-Hung Lin, Wei-Ling Chen, Chien-Ming Li, Ming-Jui Wu, Ping-Tzan Huang, Ying-Shin Chen

Open access · bronzeAbstract read
In one paragraph

Article in Healthcare technology letters, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Chia-Hung LinDepartment of Electrical Engineering, Kao-Yuan University, Kaohsiung City 82151, Taiwan.
Wei-Ling ChenDepartment of Engineering and Maintenance, Kaohsiung Veterans General Hospital, Kaohsiung City 81362, Taiwan.
Chien-Ming LiDepartment of Division of Infectious Diseases, Medicine of Chi Mei Medical Center, Tainan City 710, Taiwan.
Ming-Jui WuDepartment of Internal Medicine, Kaohsiung Veterans General Hospital, Tainan Branch, Tainan City 71051, Taiwan.
Ping-Tzan HuangDepartment of Electrical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan.
Ying-Shin ChenDepartment of Electrical Engineering, Kao-Yuan University, Kaohsiung City 82151, Taiwan.
Kaohsiung Veterans General Hospital · TWKao Yuan University · TWChi Mei Medical Center · TWNational Tsing Hua University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Blood leakages and blood loss are both serious complications during dialysis therapies. According to dialysis survey reports, these events are life-threatening issues for nephrology nurses, medical staff, and patients. When venous needle dislodgement occurs, it takes only <2.5 min of reaction time for blood loss in an adult patient, resulting in mortality. As an early-warning design, a wireless assistive technology using an integrated flexible sensor and virtual alarm unit was developed to detect blood leakage during dialysis therapies. The flexible sensor was designed using a screen print technique with printing electronic circuits on a plastic substrate. A self-organising algorithm was used to design a virtual alarm unit, consisting of a virtual direct current grid and a virtual alarm driver. In other words, this warning device was employed to identify the blood leakage levels via wireless fidelity wireless network in cloud computing. The feasibility was verified, and commercialisation designs can also be implemented in an embedded system.

Indexed as

assistive technologybiomedical electronicsbloodblood leakage detectionblood losscloud computingdialysis therapydiseasesembedded systemembedded systemsflexible sensorintegrated flexible sensormedical signal detectionmedical signal processingmedical staffnephrology nursespatient treatmentprinting electronic circuitsself-organising algorithmtelemedicinevenous needle dislodgementvirtual alarm drivervirtual alarm unitvirtual direct current gridvirtual instrumentationwireless assistive technologywireless fidelity wireless networkwireless LAN