Evidence map›Paper›PMID 30799978›Full record

ArticleBiochemia medica2019

Improving home haemodialysis: Stability evaluation of routine clinical chemistry analytes in blood samples of haemodialysis patients.

Lourens J P Nonkes, Maaike K van Gelder, Hans Kemperman, Alferso C Abrahams, Frans T J Boereboom, Maarten J Ten Berg, Karin G F Gerritsen

Open access · diamondAbstract readEvaluation Study
In one paragraph

Article in Biochemia medica, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Lourens J P NonkesDepartment of Clinical Chemistry and Haematology, University Medical Center Utrecht, Utrecht, The Netherlands.
Maaike K van GelderDepartment of Nephrology and Hypertension, University Medical Center Utrecht, Utrecht, The Netherlands.
Hans KempermanDepartment of Clinical Chemistry and Haematology, University Medical Center Utrecht, Utrecht, The Netherlands.
Alferso C AbrahamsDepartment of Nephrology and Hypertension, University Medical Center Utrecht, Utrecht, The Netherlands.
Frans T J BoereboomDiakonessenhuis, Utrecht, The Netherlands and Dianet Dialysis Center, Utrecht, The Netherlands.
Maarten J Ten BergDepartment of Clinical Chemistry and Haematology, University Medical Center Utrecht, Utrecht, The Netherlands.
Karin G F GerritsenDepartment of Nephrology and Hypertension, University Medical Center Utrecht, Utrecht, The Netherlands.
University Medical Center Utrecht · NLDianet · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionA growing number of dialysis patients is treated with home haemodialysis. Our current pre-analytical protocols require patients to centrifuge the blood sample and transfer the plasma into a new tube at home. This procedure is prone to errors and precludes accurate bicarbonate measurement, required for determining dialysate bicarbonate concentration and maintaining acid-base status. We therefore evaluated whether cooled overnight storage of gel separated plasma is an acceptable alternative. MATERIALS AND

methodsVenous blood of 34 haemodialysis patients was collected in 2 lithium heparin blood collection tubes with gel separator (LH PSTTM II, REF 367374; Becton Dickinson, New Jersey, USA). One tube was analysed directly for measurement of bicarbonate, potassium, calcium, phosphate, glucose, urea, lactate, aspartate aminotransferase (AST), and lactate dehydrogenase (LD); whereas the other was centrifuged and stored unopened at 4 °C and analysed 24 h later. To measure analyte stability after 24 h of storage, the mean difference was calculated and compared to the total allowable error (TEa) which was used as acceptance limit.

resultsPotassium (Z = - 4.28, P < 0.001), phosphate (Z = - 3.26, P = 0.001), lactate (Z = - 5.11, P < 0.001) and AST (Z = - 2.71, P = 0.007) concentrations were higher, whereas glucose (Z = 4.00, P < 0.001) and LD (Z = 3.13, P = 0.002) showed a reduction. All mean differences were smaller than the TEa and thus not clinically relevant. Bicarbonate (Z = 0.69, P = 0.491), calcium (Z = - 0.23, P = 0.815) and urea (Z = 0.81, P =0.415) concentrations were stable.

conclusionsOur less complex, user-friendly pre-analytical procedure resulted in at least 24 h stability of analytes relevant for monitoring haemodialysis, including bicarbonate. This allows shipment and analysis the next day.

Indexed as

Blood Specimen CollectionBicarbonatesBlood GlucoseBlood PreservationCalciumClinical Chemistry TestsHemodialysis, HomeHumansLactic AcidPotassiumBicarbonatesBlood GlucoseCalciumLactic AcidPotassiumbicarbonatesblood specimen collectionclinical chemistry testshaemodialysis

Identifiers

PMID30799978
PMCPMC6366947
OpenAlexW2914735819

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.