Evidence map›Paper›PMID 30795547›Full record

ArticleSensors (Basel, Switzerland)2019

Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection.

Maik Bertke, Jiushuai Xu, Michael Fahrbach, Andi Setiono, Hutomo Suryo Wasisto, Erwin Peiner

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Maik BertkeInstitute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Str. 66, 38106 Braunschweig, Germany. M.Bertke@tu-bs.de.ORCID 0000-0003-3902-8521
Jiushuai XuInstitute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Str. 66, 38106 Braunschweig, Germany. Jiushuai.Xu@tu-bs.de.ORCID 0000-0002-7279-4378
Michael FahrbachInstitute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Str. 66, 38106 Braunschweig, Germany. M.Fahrbach@tu-bs.de.
Andi SetionoInstitute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Str. 66, 38106 Braunschweig, Germany. A.Setiono@tu-bs.de.
Hutomo Suryo WasistoInstitute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Str. 66, 38106 Braunschweig, Germany. H.Wasisto@tu-bs.de.ORCID 0000-0002-4522-3625
Erwin PeinerInstitute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Str. 66, 38106 Braunschweig, Germany. E.Peiner@tu-bs.de.ORCID 0000-0001-5801-813X
Technische Universität Braunschweig · DE

Funding

Niedersächsisches Vorab QUANOMET NP2-2
6 · The paper itself

Abstract

In this paper, a self-out-readable, miniaturized cantilever resonator for highly sensitive airborne nanoparticle (NP) detection is presented. The cantilever, which is operated in the fundamental in-plane resonance mode, is used as a microbalance with femtogram resolution. To maximize sensitivity and read-out signal amplitude of the piezo-resistive Wheatstone half bridge, the geometric parameters of the sensor design are optimized by finite element modelling (FEM). The electrical read-out of the cantilever movement is realized by piezo-resistive struts at the sides of the cantilever resonator that enable real-time tracking using a phase-locked loop (PLL) circuit. Cantilevers with minimum resonator mass of 1.72 ng and resonance frequency of ~440 kHz were fabricated, providing a theoretical sensitivity of 7.8 fg/Hz. In addition, for electrostatic NP collection, the cantilever has a negative-biased electrode located at its free end. Moreover, the counter-electrode surrounding the cantilever and a µ-channel, guiding the particle-laden air flow towards the cantilever, are integrated with the sensor chip. µ-channels and varying sampling voltages will also be used to accomplish particle separation for size-selective NP detection. To sum up, the presented airborne NP sensor is expected to demonstrate significant improvements in the field of handheld, micro-/nanoelectromechanical systems (M/NEMS)-based NP monitoring devices.

Indexed as

cantilever resonatorelectrostatic particle collectionFEM simulationsnanoparticlesself-reading femtogram balance

Identifiers

PMID30795547
PMCPMC6412668
OpenAlexW2917635740

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked