ArticleNMR in biomedicine2019
Imaging of the region of the osteochondral junction (OCJ) using a 3D adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-cones) sequence at 3 T.
Article in NMR in biomedicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 28 citations in OpenAlex.
- Fusion of photon-counting CT and MRI improves assessment of the knee: a pilot study.Osteoarthritis imaging · 2026Article
- Clinical applications of UTE-T2* in knee MRI.Skeletal radiology · 2026Review
- Quantitative Ultrashort Echo Time Magnetization Transfer Imaging of the Osteochondral Junction: An In Vivo Knee Osteoarthritis Study.Journal of imaging · 2025Article
- Quantitative ultrashort echo time MR imaging of knee osteochondral junction: An ex vivo feasibility study.NMR in biomedicine · 2024Article
- High contrast cartilaginous endplate imaging in spine using three dimensional dual-inversion recovery prepared ultrashort echo time (3D DIR-UTE) sequence.Skeletal radiology · 2024Article
- Clinical application of ultrashort echo time (UTE) and zero echo time (ZTE) magnetic resonance (MR) imaging in the evaluation of osteoarthritis.Skeletal radiology · 2023Review
- Article
- Ultrashort echo time magnetic resonance imaging of the osteochondral junction.NMR in biomedicine · 2023Review
- Making the invisible visible-ultrashort echo time magnetic resonance imaging: Technical developments and applications.Applied physics reviews · 2022Review
- Structural clues to articular calcified cartilage function: A descriptive review of this crucial interface tissue.Journal of anatomy · 2022Review
- Preliminary study on the assessment of early cartilage degeneration by quantitative ultrashort echo time magnetic resonance imagingQuantitative imaging in medicine and surgery · 2022Article
- Ultrashort Echo Time Magnetic Resonance Imaging Techniques: Met and Unmet Needs in Musculoskeletal Imaging.Journal of magnetic resonance imaging : JMRI · 2022Review
- Evaluation of enzymatic proteoglycan loss and collagen degradation in human articular cartilage using ultrashort echo time-based biomarkers: A feasibility study.NMR in biomedicine · 2022Article
- AcidoCEST-UTE MRI Reveals an Acidic Microenvironment in Knee Osteoarthritis.International journal of molecular sciences · 2022Article
- Articular Cartilage Assessment Using Ultrashort Echo Time MRI: A Review.Frontiers in endocrinology · 2022Review
- Editorial: Cartilage assessment using quantitative MRI.Frontiers in endocrinology · 2022Article
- High contrast cartilaginous endplate imaging using a 3D adiabatic inversion-recovery-prepared fat-saturated ultrashort echo time (3D IR-FS-UTE) sequence.NMR in biomedicine · 2021Article
- Automated cartilage segmentation and quantification using 3D ultrashort echo time (UTE) cones MR imaging with deep convolutional neural networks.European radiology · 2021Article
- Ultrashort echo time Cones double echo steady state (UTE-Cones-DESS) for rapid morphological imaging of short TMagnetic resonance in medicine · 2021Article
- High-contrast osteochondral junction imaging using a 3D dual adiabatic inversion recovery-prepared ultrashort echo time cones sequence.NMR in biomedicine · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 2 countries.
Funding
Abstract
The purpose of this study is to develop a 3D adiabatic inversion recovery prepared ultrashort echo time Cones (3D IR-UTE-Cones) sequence for high resolution and contrast imaging of the region of osteochondral junction (OCJ) of human knee joint using a clinical 3 T scanner. A feasibility study on direct imaging of the OCJ region was performed on a human patellar cartilage sample and on eight cadaveric knee joints using T
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.