Evidence map›Paper›PMID 30794241›Full record

SynthesisClinical orthopaedics and related research2018

What Markers Best Guide the Timing of Reimplantation in Two-stage Exchange Arthroplasty for PJI? A Systematic Review and Meta-analysis.

Yong Seuk Lee, Navin Fernando, Kyung-Hoi Koo, Hyun Jung Kim, Hamed Vahedi, Antonia F Chen

Open access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in Clinical orthopaedics and related research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed, 2 pooled it
4.7field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 2 syntheses or guidelines pooled it, 44 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Upcoming evidence in clinical practice of two-stage revision arthroplasty for prosthetic joint infection.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024
    Review
  9. Article
  10. Article
  11. Review
  12. Utility of D-dimer in total joint arthroplasty.World journal of orthopedics · 2023
    Review
  13. Article
  14. Article
  15. Article
  16. Future directions of postoperative spinal implant infections.Journal of spine surgery (Hong Kong) · 2020
    Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Yong Seuk LeeY. S. Lee, N. Fernando, H. Vahedi, A. F. Chen, Department of Orthopedic Surgery, Rothman Institute at Thomas Jefferson University, Philadelphia, PA, USA K.-H. Koo, Y. S. Lee, Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, South Korea N. Fernando, Department of Orthopedic Surgery, University of Washington School of Medicine, Seattle, WA, USA H. J. Kim, Institute for Evidence-based Medicine and Department of Preventive Medicine, Korea University College of Medicine, Seoul, South Korea.
Navin Fernando
Kyung-Hoi Koo
Hyun Jung Kim
Hamed Vahedi
Antonia F Chen
University of Washington · USCenter for Clinical Research (United States) · USRothman Institute · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThere is no consensus on the appropriate marker to use when deciding to perform reimplantation after two-stage exchange arthroplasty for periprosthetic joint infection (PJI). QUESTIONS/PURPOSES: What tests provide acceptable diagnostic value to guide appropriate timing of reimplantation in two-stage exchange arthroplasty for PJI?

methodsA search of online databases (MEDLINE, EMBASE, OVID, and Cochrane database) was performed containing articles that provided sensitivity and specificity values for accuracy for predicting reimplantation of the hip and/or knee. Twelve articles were included for final analysis, which included data from 1047 patients. Data that described the diagnostic accuracy of markers for reimplantation were evaluated and categorized into four main entities according to diagnostic method (serologic, synovial, tissue, and diagnostic imaging). Twelve parameters were examined, including serum erythrocyte sedimentation (ESR) rate, serum C-reactive protein (CRP), serum white blood cell (WBC) count, synovial fluid Gram stain, synovial fluid culture, synovial fluid sonication culture, synovial fluid WBC, synovial fluid polymorphonucleocyte percentage (PMN%), tissue Gram stain, tissue culture, positron emission tomography scan, and leukocyte scan. Each of the included articles was independently analyzed for risk of bias and applicability by using QUADAS-2. Statistical heterogeneity was calculated by using the Cochran Q test, and an α of 0.10 was considered significant for heterogeneity.

resultsTissue culture (sensitivity 0.82 [0.72-0.90], specificity 0.91 [0.89-0.95], diagnostic odds ratio (DOR) 46.87 [95% confidence interval {CI}, 22.03-99.69], synovial fluid PMN% (sensitivity 0.77 [0.46-0.95], specificity 0.74 [0.67-0.81], DOR 11.27 [95% CI, 2.89-43.61]), and synovial fluid culture (sensitivity 0.64 [0.52-0.74], specificity 0.96 [0.93-0.98], DOR 27.07 [95% CI, 2.55-288.00]) showed relatively high diagnostic performance. Other parameters had poorer diagnostic accuracy: ESR (sensitivity 0.56 [0.40-0.72], specificity 0.60 [0.53-0.66], DOR 2.41 [95% CI, 0.60-9.72), CRP (sensitivity 0.53 [0.39-0.67], specificity 0.72 [0.66-0.78], DOR 2.25 [95% CI, 0.09-4.63), and synovial fluid WBC count (sensitivity 0.37 [0.19-0.58], specificity 0.49 [0.41-0.57], DOR 0.94 [95% CI, 0.06-14.74). However, interpretation is limited, because only two to three studies were available for each pooled analysis. Both risks of bias and applicability concerns were low in the four domains assessed in QUADAS-2.

conclusionsThis meta-analysis suggests that no single marker was superior to all the others, and none (when used alone) is likely sufficient to confirm control of infection after the first stage of a two-stage protocol for PJI. Therefore, the current approach using multiple tools rather than a single marker is essential. Additionally, further studies must be conducted so that pooled analysis can be performed using multiple studies to determine ideal markers for reimplantation. LEVEL OF EVIDENCE: Level III, diagnostic study.

Indexed as

Device RemovalAdultAgedAged, 80 and overArthroplasty, Replacement, HipArthroplasty, Replacement, KneeBiomarkersFemaleHip ProsthesisHumansKnee ProsthesisMaleMiddle AgedPredictive Value of TestsProsthesis-Related InfectionsReoperationBiomarkers

Identifiers

PMID30794241
PMCPMC6259852
OpenAlexW2888123738

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.