Evidence map›Paper›PMID 30794222›Full record

ArticleClinical orthopaedics and related research2019

Revisions of Modular Metal-on-metal THA Have a High Risk of Early Complications.

Jason M Jennings, Samuel White, J Ryan Martin, Charlie C Yang, Todd M Miner, Douglas A Dennis

Open access · greenAbstract readComparative Study
In one paragraph

Article in Clinical orthopaedics and related research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Global mapping of institutional and hospital-based (Level II-IV) arthroplasty registries: a scoping review.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Revision total hip arthroplasty for metal-on-metal failure.Journal of clinical orthopaedics and trauma
    Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Jason M JenningsJ. M. Jennings, C. C. Yang, T. M. Miner, D. A. Dennis, Colorado Joint Replacement, Denver, CO, USA S. White, Icahn School of Medicine at Mount Sinai, New York, NY, USA J. R. Martin, OrthoCarolina, Charlotte, NC, USA J. M. Jennings, D. A. Dennis, Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA D. A. Dennis, Department of Orthopaedics, University of Colorado School of Medicine, Denver, CO, USA; and the Department of Biomedical Engineering, University of Tennessee, Knoxville, TN, USA.
Samuel White
J Ryan Martin
Charlie C Yang
Todd M Miner
Douglas A Dennis
Defense Threat Reduction Agency · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe risk of early complications is high after monoblock acetabular metal-on-metal (MoM) THA revisions. However, there is a paucity of evidence regarding clinical complications after isolated head-liner exchange of modular MoM THA. QUESTIONS/PURPOSES: The purposes of this study were (1) to describe the frequency of early complications after an isolated head-liner exchange revision of modular MoM THA; and (2) to determine whether patients who experienced complications or dislocation after head-liner exchanges had higher serum chromium (Cr) or cobalt (Co) ion levels than those who did not.

methodsA review of our institution's total joint registry retrospectively identified 53 patients who underwent 54 liner exchange revisions of a modular acetabular MoM THA. The study period was from April 2008 to April 2016 at a single tertiary care center. During this period, isolated head-liner exchanges (rather than more extensive revisions) were performed in patients if they did not have evidence of loosening of the acetabular or femoral components. Reasons for revision surgery included pain, mechanical symptoms, radiographic evidence of osteolysis, elevated serum metal ions, and MRI abnormalities with 40 of the 54 hips having pain or mechanical symptoms and 38 of 54 hips having multiple reasons for revision before surgery. Patients were excluded if they did not meet the minimum postrevision followup or had the modular liner exchange secondary to infection. All revisions were from a single manufacturer with one head-liner exchange of a MoM THA from another manufacturer excluded during the study period. The mean time from index MoM THA to modular exchange was 96 (SD ± 36) months. Because the focus of this study was early complications, we had a minimum 90-day followup duration for inclusion. Mean followup after revision was 15 months (SD ± 12); a total of 56% (30 of 54) had followup of at least 12 months' duration. Complications (dislocation, infection) and reoperations were obtained by chart review performed by individuals other than the treating physician(s). Serum metal ion levels were obtained before head-liner exchange. The median serum Cr and Co levels were 6 µg/L (range, 0-76 µg/L) and 12 µg/L (range, 0-163 µg/L), respectively.

resultsOf the 54 revision THAs, 15 (28%) developed complications. Nine (17%) occurred within 90 days of the revision surgery and 11 (20%) resulted in reoperation. The most common complication was dislocation (12 of 54 [22%]) with recurrent dislocation noted in eight of these 12 patients. All patients with recurrent dislocation continued to dislocate and underwent repeat revision. Patients with dislocation had higher median serum Cr and Co ion levels than those without dislocation (Cr: 24 [range, 11-76] versus 4 [range, 0-70], p = 0.001 [95% confidence interval {CI}, 10-57]; Co: 41 [range, 6-163] versus 8 [range, 0-133], p = 0.016 [95% CI, 6-141]). Three (6%) of the 54 patients underwent repeat surgery for deep space infection.

conclusionsComplications and reoperations are common after modular head-liner exchange in the setting of a failed MoM THA. Our study likely underestimates the frequency of complications and revisions because the followup period in this report was relatively short. Dislocation is the most common complication and elevated serum metal ion levels may be a predictor of dislocation. These findings are concerning and surgeons should be aware of the high complication risk associated with this procedure. LEVEL OF EVIDENCE: Level IV, therapeutic study.

Indexed as

Hip ProsthesisMetal-on-Metal Joint ProsthesesAgedArthroplasty, Replacement, HipBiomarkersChromiumCobaltFemaleHip JointHumansMaleMiddle AgedPostoperative ComplicationsProsthesis DesignRegistriesReoperationBiomarkersChromiumCobalt

Identifiers

PMID30794222
PMCPMC6370086
OpenAlexW2804233353

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.