Evidence map›Paper›PMID 30793264›Full record

ArticleJournal of the American Society for Mass Spectrometry2019

Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI) for Voltage-Free Liquid Chromatography-Mass Spectrometry.

Nandhini Ranganathan, Chong Li, Timothy Suder, Ahmad K Karanji, Xiaojun Li, Ziyi He, Stephen J Valentine, Peng Li

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Cholesterol impacts the formation of huntingtin/lipid complexes and subsequent aggregation.Protein science : a publication of the Protein Society · 2023
    Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nandhini RanganathanC. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA.
Chong LiC. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA.
Timothy SuderWest Virginia Wesleyan College, Buckhannon, WV, USA.
Ahmad K KaranjiC. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA.
Xiaojun LiC. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA.
Ziyi HeC. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA.
Stephen J ValentineC. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA. stephen.valentine@mail.wvu.edu.
Peng LiC. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA. peng.li@mail.wvu.edu.ORCID http://orcid.org/0000-0002-8332-7142

Funding

Developing IMS-SID/MAD-MS Instrumentation for Characterizing Intrinsically Disordered Protein StructureR01GM114494 · NIGMS · WEST VIRGINIA UNIVERSITY · PI VALENTINE, STEPHEN · 2015 to 2019
$1.4M
Division of Chemistry CHE-1553021National Institute of General Medical Sciences R01GM114494NIGMS NIH HHS R01 GM114494West Virginia University Start-up
6 · The paper itself

Abstract

Here, we report a continuous flow-based ionization method, capillary vibrating sharp-edge spray ionization (cVSSI), that nebulizes liquid sample directly at the outlet of a capillary without using high-speed nebulization gas or a high electrical field. cVSSI is built upon the recently reported VSSI principle which nebulizes bulk liquid using vibrating sharp-edges. By attaching a short piece of fused silica capillary on top of the vibrating glass slide in VSSI, liquid is nebulized at the outlet of the capillary as the result of the vibration. Utilizing standard 360-μm OD/100-μm ID capillary, cVSSI works with a wide range of flow rates from 1 μL/min to 1 mL/min. The power consumption is as low as 130 mW. ESI-like MS spectra are obtained for small molecules, peptides, and proteins. Five orders of magnitude linear response for acetaminophen solution is achieved with a limit of detection (LOD) of 3 nM. cVSSI is also demonstrated to be compatible with LC-MS analysis. Two LC-MS applications are demonstrated with cVSSI: (1) separation and detection of a mixture of small molecules and (2) bottom-up proteomics using a protein digest. A mixture of nine common metabolites was appropriately separated and detected using LC-cVSSI-MS. In the bottom-up experiment, 78 peptides were detected using LC-cVSSI-MS/MS with a protein coverage of 100% for cytochrome c, which is comparable with the coverage obtained using LC-ESI-MS. cVSSI offers a means of interfacing LC or other continuous flow-based applications to mass spectrometers with the salient features of voltage-free, flexibility, small footprint, and low power consumption.

Indexed as

IonizationLC-MSMass spectrometryVoltage-free nebulization

Identifiers

PMID30793264
PMCPMC6560627

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.