Evidence map›Paper›PMID 30792831›Full record

ArticleJournal of healthcare engineering2018

Fully Automated Lumen Segmentation Method for Intracoronary Optical Coherence Tomography.

Elżbieta Pociask, Krzysztof Piotr Malinowski, Magdalena Ślęzak, Joanna Jaworek-Korjakowska, Wojciech Wojakowski, Tomasz Roleder

Abstract read
In one paragraph

Article in Journal of healthcare engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Elżbieta PociaskDepartment of Biocybernetics and Biomedical Engineering, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Krakow, Poland.ORCID 0000-0001-8938-1089
Krzysztof Piotr MalinowskiJagiellonian University Medical College, Faculty of Health Science, Institute of Public Health, Krakow, Poland.ORCID 0000-0002-4644-6249
Magdalena ŚlęzakKCRI, Krakow, Poland.ORCID 0000-0002-3406-1907
Joanna Jaworek-KorjakowskaDepartment of Automatic Control and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Krakow, Poland.ORCID 0000-0003-0146-8652
Wojciech WojakowskiThird Department of Cardiology, Medical University of Silesia, Katowice, Poland.ORCID 0000-0002-3681-5207
Tomasz RolederThird Department of Cardiology, Medical University of Silesia, Katowice, Poland.ORCID 0000-0002-1370-7369

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Optical coherence tomography (OCT) is an innovative imaging technique that generates high-resolution intracoronary images. In the last few years, the need for more precise analysis regarding coronary artery disease to achieve optimal treatment has made intravascular imaging an area of primary importance in interventional cardiology. One of the main challenges in OCT image analysis is the accurate detection of lumen which is significant for the further prognosis. Method: In this research, we present a new approach to the segmentation of lumen in OCT images. The proposed work is focused on designing an efficient automatic algorithm containing the following steps: preprocessing (artifacts removal: speckle noise, circular rings, and guide wire), conversion between polar and Cartesian coordinates, and segmentation algorithm. Results: The implemented method was tasted on 667 OCT frames. The lumen border was extracted with a high correlation compared to the ground truth: 0.97 ICC (0.97-0.98). Conclusions: Proposed algorithm allows for fully automated lumen segmentation on optical coherence tomography images. This tool may be applied to automated quantitative lumen analysis.

Indexed as

AlgorithmsArtifactsCoronary Artery DiseaseCoronary VesselsHumansImage Interpretation, Computer-AssistedTomography, Optical Coherence

Identifiers

PMID30792831
PMCPMC6327279

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked