ArticleSensors (Basel, Switzerland)2019
A New Model and Its Application for the Dynamic Response of RGO Resistive Gas Sensor.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Gas-Sensitive Characteristics of Graphene Composite Tungsten Disulfide to Ammonia.Sensors (Basel, Switzerland) · 2022Article
- Ultra-Sensitive Photo-Induced Hydrogen Gas Sensor Based on Two-Dimensional CeONanomaterials (Basel, Switzerland) · 2022Article
- A flexible and wearable NOMicrosystems & nanoengineering · 2022Article
- Enhanced Room Temperature NOSensors (Basel, Switzerland) · 2019Article
- High-Performance UV-Assisted NOACS omega · 2019Article
- Impedance Spectroscopy-Based Reduced Graphene Oxide-Incorporated ZnO Composite Sensor for HACS omega · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
An reduced graphene oxide (RGO) resistive gas sensor was prepared to detect ammonia at room temperature, the result indicated that the desorption of gas (NH 3 ) molecules from a graphene-based sensor was difficult, which lead to a baseline drift. The responses of different concentrations were compared and studied. It was found that both the response rate and its acceleration were affected by the gas concentration. An Intermolecular Forces Based Model was established to explain the adsorption and desorption dynamic response curves. A new method was proposed based on this model. The first and second derivative extrema (FSDE) of the response curve can be attained quickly to calibrate the gas concentrations. The experiment results demonstrated that this new method could eliminate the baseline drift and was capable of increasing the efficiency of gas calibration significantly.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.